F-80

TROUBLESHOOTING AND REPAIR

F-80

AUXILIARY TRANSFORMER NO. 1 REMOVAL AND

REPLACEMENT PROCEDURE (continued)

FIGURE F.23 — AUXILIARY TRANSFORMER NO. 1 REMOVAL AND REPLACEMENT PROCEDURE.

H1 RECONNECT

TERMINALS

Return

Return to Master TOC

POWER BOARD

RECTIFIER BRIDGE

X1

X2

CB4

H2

H3

H4

H5

MAIN

CONNECTOR

X4

X3

X5

FAN

MOUNTING MOTOR

SCREW LEADS (2X)

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

REMOVAL PROCEDURE

1.Remove input power to the Power Wave 455.

2.Using the 3/8 in. nutdriver, remove the case top, sides and input access panel.

3.Perform the Capacitor Discharge

Procedure.

4.Using the 3/8 in. nutdriver, remove the case back.

5.Remove leads X1 and X2 from the power board rectifier bridge. Refer to Figure F.23.

6.Cut X3 and X5 from the fan motor leads. Leave enough lead length to splice in the new transformer leads.

7.Remove lead X4 from the main contac- tor coil terminal.