F-5

TROUBLESHOOTING AND REPAIR

F-5

TROUBLESHOOTING GUIDE

POWER WAVE

Observe all Safety Guidelines detailed throughout this manual.

PROBLEMS

POSSIBLE AREAS OF

RECOMMENDED

(SYMPTOMS)

MISADJUSTMENT(S)

COURSE OF ACTION

 

 

 

 

 

 

 

OUTPUT PROBLEMS

 

 

 

 

 

 

 

Major physical or electrical dam-

1.

Contact your local authorized

1.

Contact the Lincoln Electric

age is evident when the sheet

 

Lincoln Electric Field Service

 

Service Department, 216-383-

metal cover(s) are removed.

 

Facility for technical assistance.

 

2531 or 1-800-833-9353

 

 

 

 

(WELD).

 

 

 

 

 

The machine is dead -- no output --

1.

Make certain the input power

1.

Check the input power switch

no fan -- no LEDs.

 

switch SW1 is in the ON posi-

 

(SW1) for proper operation.

 

 

tion.

 

Also check the associated leads

 

 

 

 

for loose or faulty connections.

 

2.

Check the main input fuses. If

 

See wiring diagram.

 

 

open, replace.

 

 

 

 

 

2.

Check CB4 for proper operation.

 

3.

Check the 6 amp circuit breaker

 

 

 

 

(CB4). Reset if tripped.

3.

Perform the T1 Auxiliary

 

 

 

 

Transformer Test.

 

4.

Make certain the reconnect

 

 

 

 

panel is configured correctly for

4.

Perform the Power Board Test.

 

 

the applied input voltage.

 

 

 

 

 

 

 

The main input fuses (or breaker)

1.

Make certain the fuses or break-

1.

Check the reconnect switches

repeatedly fail.

 

ers are properly sized.

 

and associated wiring. See

 

 

 

 

wiring diagram.

 

2.

Make certain the reconnect

 

 

 

 

panel is configured properly for

2.

Perform the Input Rectifier

 

 

the applied input voltage.

 

Test.

 

3.

The welding procedure may be

3.

Perform the Switch Board

 

 

drawing too much input current

 

Test.

 

 

or the duty cycle may be too

 

 

 

 

high. Reduce the welding cur-

 

 

 

 

rent and/or reduce the duty

 

 

 

 

cycle.

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

-----------------------------------------------------------------------------------------------------------------------------

POWER WAVE 455/POWER FEED 10

Page 69
Image 69