Return to Master TOC
Return to Master TOC
Return to Master TOC
Return to Master TOC
TROUBLESHOOTING AND REPAIR |
| ||||||
| STATUS LED ERROR CODE TABLE (Continued) |
|
| ||||
|
|
|
|
|
|
| |
POWER SOURCE |
| ERROR CODE |
|
|
|
| |
ERRORS |
| LED SEQUENCE |
|
|
|
| |
|
|
|
|
| |||
#31 Primary over current | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] |
|
|
|
#32 Capacitor “A” under voltage | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
#33 Capacitor “B” under voltage | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
| [0.4 sec.off] [0.4 sec.red] |
|
|
|
| |
#34 Capacitor “A” over voltage | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
| [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] [0.4 sec.red] |
|
| ||
#35 Capacitor “B” over voltage | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
| [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] | |||
|
| [0.4 sec.red] |
|
|
|
|
|
#36 Thermal overload |
| [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | ||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
| [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] | |||
|
| [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] |
|
|
|
#37 Machine failed soft start | [2 sec.green] | [1.2 sec.red] [0.4 sec.off] | [1.2 sec.red] | [0.4 sec.off] | |||
|
| [1.2 sec.red] | [1.6 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
| [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] [0.4 sec.red] | [0.4 sec.off] | |||
|
| [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | [0.4 sec.off] | [0.4 sec.red] | |
|
|
|
|
|
|
|
|
CAUTION
If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call