Return to Section TOC

to Section TOC

Return to Master TOC

to Master TOC

F-40

TROUBLESHOOTING AND REPAIR

F-40

 

AUXILIARY TRANSFORMER NO. 1 TEST (continued)

 

FIGURE F.9 — AUXILIARY TRANSFORMER NO. 1 TEST.

POWER BOARDMAIN

RECTIFIER BRIDGE

CONTACTOR

X1

X4

X2

X3

X5

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

TEST PROCEDURE

1.Remove the main input supply power to the Power Wave 455 machine.

2.Using the 3/8 in. nutdriver, remove the case sides and top.

3.Perform the Capacitor Discharge

Procedure.

FAN MOTOR

LEADS

4.Locate secondary leads X1 and X2 (at power board rectifier bridge). Refer to Figure F.9.

5.Locate secondary leads X3 and X5 (fan motor leads).

6.Locate secondary lead X4 (at main contactor).

POWER WAVE 455/POWER FEED 10

Page 104
Image 104
Lincoln Electric SVM135-B service manual FAN Motor Leads