Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Section TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

Return to Master TOC

A-14

INSTALLATION

A-14

Setting Wire Drive Acceleration Rate Using

(All software versions)

DIP Switch S1 on the Control Box Motherboard

 

 

 

DIP SWITCH 6

DIP SWITCH 7

DIP SWITCH 8

 

 

 

 

Acceleration 1 (slow)

Off

Off

On

 

 

 

 

Acceleration 2

Off

On

Off

 

 

 

 

Acceleration 3

Off

On

On

 

 

 

 

Acceleration 4

On

Off

Off

 

 

 

 

Acceleration 5 (fast ) (factory setting)

Off

Off

Off

 

 

 

 

SETTING DIP SWITCHES IN THE WIRE

 

 

 

 

 

 

 

 

 

 

 

 

ON

 

 

 

 

 

 

 

 

DRIVE

 

 

 

 

 

 

 

 

 

 

 

1

2

3

4

5

6

7

8

 

 

 

 

 

 

S1

 

 

 

 

 

 

 

 

 

 

There is one DIP switch bank on the control board of

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

the wire drive. It’s labeled S1 and is located and ori-

 

 

 

FIGURE A.4

ented as shown in Figure A.4.

 

 

 

S1 DIP Switch on Wire Drive Control Board (For software version S24029-All & S24467)

Switch

Off

 

 

 

On

 

 

 

 

 

1

Network Group ID, MSB

(Assigns Wire Drive to a specific group)

 

 

 

 

 

2

Network Group ID, LSB

(Assigns Wire Drive to a specific group )

 

 

 

 

 

3

Network Feed Head ID, MSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

4

Network Feed Head ID

 

(Assigns feed head number to wire drive)

 

 

 

 

 

5

Network Feed Head ID, LSB

(Assigns feed head number to wire drive)

 

 

 

 

 

 

6

Spare

 

 

 

 

 

 

 

 

7

Electrode Sense Polarity = Positive

 

Electrode Sense Polarity = Negative

 

 

 

 

 

 

 

 

 

 

 

Switch position must match polarity of weld cable attached to feed plate.

 

 

 

 

 

 

8

Gear Box Ratio = Low

 

 

 

Gear Box Ratio = High

 

 

 

 

 

 

 

 

 

 

 

Switch position must match actual gear box ratio of wire drive.

 

 

 

 

 

 

Note: the factory shipped settings for all of the S1 switches is “OFF”.

POWER WAVE 455/POWER FEED 10

Page 20
Image 20
Lincoln Electric SVM135-B service manual Setting DIP Switches in the Wire Drive, Figure A.4