Lincoln Electric SVM135-B service manual Probe Acceptable Meter Readings, Input Contactor Test

Models: SVM135-B

1 182
Download 182 pages 15.74 Kb
Page 97
Image 97

Return to Section TOC

to Section TOC

Return to Master TOC

to Master TOC

F-33

TROUBLESHOOTING AND REPAIR

F-33

INPUT RECTIFIER TEST (continued)

TABLE F.2 — INPUT RECTIFIER TEST POINTS AND ACCEPTABLE READINGS.

TEST POINT TERMINALS

ANALOG METER X10 RANGE

+ Probe

- Probe

Acceptable Meter Readings

A

NEG

Greater than 1000 ohms

B

NEG

Greater than 1000 ohms

C

NEG

Greater than 1000 ohms

A

POS

Less than 100 ohms

B

POS

Less than 100 ohms

C

POS

Less than 100 ohms

NEG

A

Less than 100 ohms

NEG

B

Less than 100 ohms

NEG

C

Less than 100 ohms

POS

A

Greater than 1000 ohms

POS

B

Greater than 1000 ohms

POS

C

Greater than 1000 ohms

 

 

 

Return

Return to Section TOC

Return to Section TOC

Return

Return to Master TOC

Return to Master TOC

7.If the input rectifier does not meet the acceptable readings outlined in the table, the component may be faulty. Replace.

NOTE: Before replacing the input rectifier, perform the Switch Board Test and the

Input Contactor Test.

8.When installing a new input rectifier, see Input Rectifier Removal and Replacement procedure.

9.If the input rectifier is good, be sure to reconnect the positive and negative leads to the correct terminals and torque to 31 in/lbs. See wiring diagram.

10.Replace any RTV sealant previously removed.

11.Install the case top.

POWER WAVE 455/POWER FEED 10

Page 97
Image 97
Lincoln Electric SVM135-B service manual Probe Acceptable Meter Readings, Input Contactor Test