F-26 TROUBLESHOOTING AND REPAIRF-26
SWITCH BOARD TEST (continued)
FIGURE F.2 — RECONNECT SWITCHES.
19D
19C
RECONNECT
SWITCHES
Return to Section TOC
Return to Section TOC
Return to Master TOC
Return to Master TOC
TEST PROCEDURE
1.Remove input power to the Power Wave 455.
2.Using the 3/8 in. nutdriver, remove the case top and sides.
3.Perform the Capacitor Discharge
Procedure.
4.Locate label and remove leads 19C and 19D from the reconnect switches with the 3/8 in. wrench. Note lead placement for reassembly. Clear leads. Refer to Figure F.2.
5.Using the Analog ohmmeter, perform the resistance tests detailed in Table F.1. Refer to Figure F.3 for the test points.