F-27TROUBLESHOOTING AND REPAIRF-27

SWITCH BOARD TEST (continued)

FIGURE F.3 — SWITCH BOARD TEST POINTS.

SWITCH

BOARD

Return to Master TOC

11/12

OR

15/16

6.If any test fails replace both switch boards. See Switch Board Removal and Replacement.

7.If the switch board resistance tests are OK, check the molex pin connections and associated wiring from the switch boards to the control board. See wiring diagram.

-20 +19

13/14

OR

17/18

8.Reconnect leads 19C and 19D to the reconnect switches. Ensure that the leads are installed in the same location they were removed from.

9.Install the right and left case sides using the 3/8 in. nutdriver.

Return to Master TOC

TABLE F.1 — SWITCH BOARD RESISTANCE TEST.

APPLY POSITIVE TEST

APPLY NEGATIVE TEST

NORMAL

PROBE TO TERMINAL

PROBE TO TERMINAL

RESISTANCE READING

 

 

 

+19

11/12 OR 15/16

Greater than 1000 ohms

+19

13/14 OR 17/18

Greater than 1000 ohms

11/12 OR 15/16

- 20

Greater than 1000 ohms

13/14 OR 17/18

- 20

Greater than 1000 ohms

- 20

11/12 OR 15/16

Less than 100 ohms

- 20

13/14 OR 17/18

Less than 100 ohms

11/12 OR 15/16

+19

Less than 100 ohms

13/14 OR 17/18

+19

Less than 100 ohms

 

 

 

POWER WAVE 455/POWER FEED 10

Page 91
Image 91
Lincoln Electric SVM135-B service manual 27TROUBLESHOOTING and REPAIRF-27, 11/12 15/16, 20 +19 13/14 17/18