F-11

TROUBLESHOOTING AND REPAIR

F-11

STATUS LED ERROR CODE TABLE

NOTE: The error code signal sequence is always preceeded by a 2 second green light. If more than one error code is present, a 4 second off signal will separate the individual error code signals. Note that the [2 sec.green] is only displayed at the beginning of the entire code sequence, not between codes if more than one error code is present.

Example: (Code. #11 “one long red” followed by “one short red”) followed by (Code. #21 “two long reds” followed by “one short red”).

[2 sec.green] [1.2 sec.red] [1.6 sec.off] [0.4 sec.red] [4.0 sec.off] [1.2 sec.red] [0.4 sec.off] [1.2 sec.red] [1.6 sec.off] [0.4 sec.red]

DIGITAL COMMUNICATION

ERROR CODE LED

 

 

 

 

 

 

ERRORS

SEQUENCE

 

 

 

 

 

 

 

 

 

 

 

 

#11 CAN bus off (Excessive

[2 sec.green]

[1.2 sec.red] [1.6 sec.off] [0.4 sec.red]

 

 

number of communication errors).

 

 

 

 

 

 

 

 

 

#12 Ul time out (Loss of communi-

[2 sec.green]

[1.2

sec.red]

[1.6

sec.off]

[0.4

sec.red]

[0.4

sec.off]

cation to control box).

[0.4 sec.red]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WELDING FILE ERRORS

ERROR CODE LED SEQUENCE

 

 

 

 

 

 

 

 

 

 

 

 

 

 

#21 Unprogrammed mode

[2 sec.green]

[1.2

sec.red]

[0.4

sec.off]

[1.2

sec.red]

[1.6

sec.off]

 

[0.4 sec.red]

 

 

 

 

 

 

 

 

#22 Empty weld table

[2 sec.green]

[1.2

sec.red]

[0.4

sec.off]

[1.2

sec.red]

[1.6

sec.off]

 

[0.4 sec.red] [0.4 sec.off] [0.4 sec.red]

 

 

 

 

#23 Weld table check sum (table is

[2 sec.green]

[1.2

sec.red]

[0.4

sec.off]

[1.2

sec.red]

[1.6

sec.off]

corrupt)

[0.4 sec.red] [0.4 sec.off] [0.4 sec.red] [0.4 sec.off] [0.4 sec.red]

 

 

 

 

 

 

 

 

 

 

 

CAUTION

If for any reason you do not understand the test procedures or are unable to perform the tests/repairs safely, contact the Lincoln Electric Service Department for technical troubleshooting assistance before you proceed. Call 216-383-2531 or 1-800-833-9353.

-----------------------------------------------------------------------------------------------------------------------------

POWER WAVE 455/POWER FEED 10

Page 75
Image 75