A-12

INSTALLATION

A-12

S1 DIP Switch Bank on Control Box Motherboard (For software version S24004-3 & up)

 

Switch

Off

 

On

 

 

 

 

 

 

1

Standard speed gearbox limits adjustable

High speed gearbox limits adjustable

 

 

 

 

 

 

2

WFS Display = inches/minute

WFS Display = meters/minute

 

 

 

 

 

 

3

Left Display is always preset WFS

Left Display is preset WFS when weld current is not flowing

 

 

 

 

 

Left Display is actual weld current when weld current is flowing

 

 

 

 

 

 

 

 

CC modes override this switch regardless of position. Left Display is always preset weld cur-

 

 

 

rent when weld current is not flowing and actual weld current when weld current is flowing

 

 

 

 

 

 

4

Run-in = Minimum Speed Available

Run-in = weld WFS

 

 

 

 

 

 

 

 

If any option containing a Run-in setting is connected to the motherboard, it automatically

 

 

 

overrides this switch regardless of position.

 

 

 

 

 

 

5

Memory change with trigger disabled

Memory change with trigger enabled

 

 

 

 

 

 

 

6

Acceleration, MSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

7

Acceleration

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

8

Acceleration, LSB

(Sets acceleration rate for wire drive) see below

 

 

 

 

 

 

 

S2 DIP Switch Bank on Control Box Motherboard (For software version S24004-3 & up)

Switch

Off

 

On

 

 

 

 

1

Network Group ID, MSB

(Assigns Control Box to a specific group) (Off is factory setting)

 

 

 

 

2

Network Group ID, LSB

(Assigns Control Box to a specific group ) (Off is factory setting)

 

 

 

 

3

Spare

 

 

 

 

 

 

4

Spare

 

 

 

 

 

 

5

Spare

 

 

 

 

 

6

Must be off for normal operation

Adjust lower limits

 

 

 

7

Must be off for normal operation

Adjust upper limits

 

 

 

8

Must be on for European units only

 

 

 

 

 

Note: the factory shipped settings for all of the S1 and S2 switches is “OFF”.

MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left. LSB - Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right.

POWER WAVE 455/POWER FEED 10

Page 18