The value of the active set up parameter is shown on the MSP2 panel digital display. The value can be modi- fied with the Set switch. The Set switch is an up/down center-off momentary toggle switch. Moving the switch bat up or down adjusts the displayed value in the cor- responding direction. Holding the switch in either direc- tion will cause the display to move quickly in the corre- sponding direction until the switch is released, or the upper or lower parameter limit is reached.

To energize the output studs in either CC/Stick mode, the right Control/Display panel knob, labeled Volts/Trim, must be used. The Volts/Trim knob must be turned clockwise roughly a quarter revolution to energize the output studs. (The Volts/trim display will indicate ‘On’ when the studs are energized.) Similarly, turning the knob a quarter turn counter- clockwise de-energizes the output studs. If a CC/Stick weld mode is entered through use of the Dual Procedure, the studs will be in the same state as when they were last used. If a CC/Stick weld mode is entered through a Memory recall, the studs will be de- energized.

CONTROL BOX PANELS -- SET UP CONTROLS DESCRIPTION

Certain large option panels can modify the set up parameters Preflow, Run In, Arc Control, Burnback, Postflow, and Crater. The meaning of those parame- ters, and their maximum and minimum values, follows.

Preflow - Time delay after the trigger is pulled, but before weld starts, during which shielding gas flows. Weld start is defined as the time when both the power source is energized and the Wire Drive begins feeding wire. Adjustable from 0.0 (Off) to 2.5 seconds in 0.1s increments.

Run In - Wire feed speed during arc starting. Wire Drive will feed wire at the Run In speed for one sec- ond, or until weld current flows. Low speed gear range: Off (Run In speed equals weld wire feed speed) or adjustable from 50 to 150 IPM (1.25 to 3.80 MPM). High speed gear range: Off (Run In speed equals weld wire feed speed) or adjustable from 75 to 150 IPM (2.00 to 3.80 MPM). NOTE: Run In settings over 150 IPM produce strange display values used for troubleshooting and service. If encountered, reset Run In to 150 IPM or less.

Arc Control - Unitless characteristic, also known as Inductance or Wave Control. Allows operator to vary the arc characteristics from “soft” to “harsh” in all weld modes. Adjustable from -10.0 to 10.0 in increments of 0.1. Off (0.0) is nominal.

Burnback - Time delay after the trigger is released- during which the power source remains energized but the Wire Drive stops feeding wire. Adjustable from 0.00 (Off) to 0.25 seconds in 0.01 second increments.

Postflow - Time delay after burnback is complete, during which shielding gas flows. Adjustable from 0.0 (Off) to 10.0 seconds in 0.1 second increments.

Crater - Used only when welding with the 4-Step trig- ger mode. Can be set to Off or On. When On, Adjustments can be made to WFS and Volts/Trim on the Control/Display panel. These settings are then used for ‘cratering’ when in the 4-Step trigger mode (see explanation of 2 Step and 4 Step operation below). When Off, ‘cratering’ is not possible.

CONTROL BOX -- PC BOARD ADJUSTMENTS

The Control Box Mother board provides the capability to adjust some wire feeding parameters as follows:

Acceleration: The motor acceleration can be varied in five steps, from slow to fast. See “Setting DIP Switches in the Control Box” section.

Burnback: For the options which cannot adjust the Burnback set up parameter (CV/G and M panels) a PC board adjustment (trimmer R5) is provided. The range is 0.0 to 0.25 seconds, increasing in the clock- wise direction. This is ignored by options which have the ability to adjust Burnback (MX2 and MSP2 pan- els).

Run In: For the options which cannot adjust the Run In set up parameter (CV/G and M panels) a PC board DIP switch setting is provided. In one position, the run in speed will be the minimum Wire Drive WFS. At the other setting, run in will occur at the same speed as set on the WFS knob. This DIP switch setting is ignored by options which have the ability to adjust Run In (MX2 and MSP2 panels). See “Setting DIP Switches in the Control Box” section.

POWER WAVE 455/POWER FEED 10

Page 47
Image 47
Lincoln Electric SVM135-B Control BOX Panels -- SET UP Controls Description, Control BOX -- PC Board Adjustments