INSTALLATION |
S1 DIP Switch Bank on Control Box Motherboard (For software version S24456)
| Switch | Off |
| On |
|
|
|
|
|
| |
1 | Standard speed gearbox limits adjustable | High speed gearbox limits adjustable |
| ||
|
|
|
|
| |
2 | WFS Display = inches/minute | WFS Display = meters/minute |
| ||
|
|
|
|
| |
3 | Left Display is always preset WFS | Left Display is preset WFS when weld current is not flowing |
| ||
|
|
|
| Left Display is actual weld current when weld current is flowing |
|
|
|
|
|
| |
|
| CC modes override this switch regardless of position. Left Display is always preset weld cur- |
| ||
|
| rent when weld current is not flowing and actual weld current when weld current is flowing |
| ||
|
|
|
|
| |
4 |
| ||||
|
|
|
|
| |
|
| If any option containing a |
| ||
|
| overrides this switch regardless of position. |
| ||
|
|
|
|
| |
5 | Memory change with trigger disabled | Memory change with trigger enabled |
| ||
|
|
|
|
| |
6 | Acceleration, MSB | (Sets acceleration rate for wire drive) see below |
| ||
|
|
|
|
| |
7 | Acceleration | (Sets acceleration rate for wire drive) see below |
| ||
|
|
|
|
| |
8 | Acceleration, LSB | (Sets acceleration rate for wire drive) see below |
| ||
|
|
|
|
|
|
Note: the factory shipped settings for the S1 switches are as follows:
|
|
| ||
S2 DIP Switch Bank on Control Box Motherboard (For software version S24456) | ||||
|
|
|
|
|
Switch | Off |
|
| On |
|
|
|
| |
1 | Network Group ID, MSB | (Assigns Control Box to a specific group) (Off is factory setting) | ||
|
|
|
| |
2 | Network Group ID, LSB | (Assigns Control Box to a specific group ) (Off is factory setting) | ||
|
|
|
| |
3 |
| |||
|
|
|
|
|
4 | Power Feed 10 / Dual |
|
| Power Feed 11 |
|
|
| ||
5 | Procedure Change with Trigger “OFF” | Procedure Change with Trigger “ON” | ||
|
|
|
|
|
6 | Set lower limits |
|
|
|
|
|
|
|
|
7 | Set upper limits |
|
|
|
|
|
| ||
8 | Must be on for all units (Permits selection of extended modes) | |||
|
|
|
|
|
Note: the factory shipped settings for the S2 switches are as follows: |
| ||
(and Dual) Domestic - switches | (and Dual) European - switches | ||
Domestic - switches | European - switches | ||
MSB - Most Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the left. | |||
LSB - | Least Significant Bit or Byte. This is the bit in a binary number or DIP switch bank that is furthest to the right. |
POWER WAVE 455/POWER FEED 10