Motorola ATCA-717 manual Power Consumption

Models: ATCA-717

1 156
Download 156 pages 224 b
Page 40
Image 40

Installation

Requirements

 

 

10

Figure 2: Location of Critical Blade Temperature Spots (Blade Bottom Side)

Power Consumption

The blade′s power requirements depend on the installed hardware accessories. If you want to install accessories on the board, the load of the respective accessory has to be added to that of the blade.In the following table you will find typical examples of power requirements with and without accessories installed. For information on the accessories’ power requirements, refer to the documentation delivered together with the respective accessory or consult your local Motorola representative for further details.aaaa

The blade must be connected to a TNV−2 or a safety−extra−low−voltage (SELV) circuit. A TNV−2 circuit is a circuit whose normal operating voltages exceed the limits for a SELV circuit under normal operating conditions, and which is not subject to overvoltages from telecommunication networks.

Table 5: Power Requirements

Characteristic

Value

Rated Voltage

−48VDC to −60VDC

Exception in the US and Canada

−48VDC

Operating Voltage

−40.5VDC to −72VDC

Exception in the US and Canada

−40.5VDC to −60VDC

40

PENT/ATCA−717

Page 40
Image 40
Motorola ATCA-717 manual Power Consumption