Switch Settings

Installation

 

 

SBlade Malfunction

Switches marked as ’reserved’ might carry production−related functions and can cause the blade to malfunction if their setting is changed.

Therefore, do not change settings of switches marked as ’reserved’. The setting of switches which are not marked as ’reserved’ has to be checked and changed before blade installation.

SBlade Damage

Setting/resetting the switches during operation can cause blade damage. Therefore, check and change switch settings before you install the blade.

Table 6: Switch Settings

Switch

Description

SW2−1

Reserved (default: OFF)

SW2−2

Reserved (default: OFF)

SW2−3

Clear CMOS RAM contentaa

 

OFF: Normal operation (default)

 

ON: Clear CMOS RAM

 

For the exact procedure of how to clear the CMOS RAM content,

 

i.e. restore the default BIOS settings, refer toasection "Restoring

 

BIOS Default Settings" on pagea91.a

SW2−4

BIOS crisis recovery mode

 

OFF: Disabled (default)

 

ON: Enabled

 

For details refer toasection "BIOS Crisis Recovery Mode" on

 

pagea86.

SW3−1

Reserved (default: OFF)

SW3−2

Reserved (default: OFF)

SW3−3

Reserved (default: OFF)

SW3−4

Serial COM interface swapping at blade start−up

 

OFF: No swapping (default)

 

As a result, COM1 and COM2 are accessible at an installed RTM,

 

COM3 and COM4 are accessible at an installed CMC module

 

ON: COM1 is swapped with COM 3, and COM 2 is swapped

 

with COM 4

 

As a result, COM1 and COM2 are accessible at an installed CMC

 

module, and COM3 and COM4 are accessible at an installed

 

RTM

PENT/ATCA−717

43

Page 43
Image 43