Installation | Requirements |
|
|
Requirement | Operating | Non−Operating |
Rel. Humidity | 5% to 95% non | 5% to 95% non condensing |
| condensing at +40° | at +40°C |
Altitude | ||
Vibration |
|
|
20 to 2000Hz | 2 g(RMS) random | 2 g(RMS) random |
Shock | 5 g/30 ms half sine | 15 g/11 ms half sine |
Free Fall | aa | 1,200 mm/all edges and |
|
| corners (packed state) |
|
| 100 mm/3 axis (unpacked) |
To guarantee proper blade operation, you have to make sure that the temperatures at the following locations are not exceeded. If not stated otherwise, the temperatures should be measured by placing a sensor exactly at the given locations.aaa
Location No. | Component | Temperature Limit |
1 | Pentium M CPU 1) | 100 °C |
2 | Intel 82540EM Gbit Ethernet controller | 100 °C |
3 | Intel 6300ESB Southbridge | 105 °C |
4 | Lithium battery | 70 °C |
5 | Intel 82546EB/GB Dual Gbit Ethernet | 90 °C |
| controller |
|
6 | Electrolytic capacitor CE9902 | 100 °C |
7 | Electrolytic capacitor CE9903 | 100 °C |
8 | Ericsson DC/DC converter | 90 °C |
9 | QM48T DC/DC converter | 115 °Ca |
|
| (105 °C coated blade variant) |
10 | Power MOSFET IRF 6603 | 105 °C |
1)Temperature must be measured via on−die sensor which can be accessed via IPMI
38 | PENT/ATCA−717 |