WLAN Application Gateway 2246 installation 97

4Repeat steps 1-3 for each additional WLAN IP Telephony Manager 2245. The mounting plate is designed to provide the correct minimum spacing between units. When mounting multiple units, stack the units in the rack as closely as possible.

—End—

LAN connection

Use an RJ-45 cable to connect the NETWORK port on the WLAN IP Telephony Manager 2245 to the connecting port on the Ethernet switch.

Power connection

Follow the steps in Procedure 4 "Connecting the power" (page 97) to connect the power to the WLAN IP Telephony Manager 2245.

Procedure 4

Connecting the power

Step Action

1Connect the power plug from the AC adapter to the jack labeled PWR on the WLAN IP Telephony Manager 2245.

WARNING

Use only the provided Class II AC adapter with output 24V DC, 1A.

2Plug the AC adapter into a 110V AC outlet to supply power to the WLAN IP Telephony Manager 2245.

The system cycles through diagnostic testing and the LEDs blink for approximately one minute.

3When the system is ready for use, verify the following:

a.ERROR LED is off.

b.Status 1 is blinking.

—End—

WLAN Application Gateway 2246 installation

For information about installing the optional WLAN Application Gateway 2246, see Appendix "WLAN Application Gateway 2246" (page 147).

Nortel Communication Server 1000

WLAN IP Telephony Installation and Commissioning

NN43001-504 01.02 Standard

Release 5.0 15 June 2007

Copyright © 2004-2007, Nortel Networks

Page 97