OfficeServ 7100 Call Server Programming Guide
[845] WLAN PARAMETERS
This MMC modifies the WLAN parameters.
The SYSTEM KEY is used internally to distinguish between systems when registering a terminal. The default value is ‘00000’, but this must be changed to another value to enable the use of WLAN terminals. In addition, the SYSTEM KEY serves as an identification ID when a WLAN terminal connects to the WBS24.
The default value of the SYSTEM ID, ‘WBS24’, must also be changed to another value in order to use multiple systems in one area. The DNS setting for WLAN is additionally de- scribed in this MMC.
Set the network configuration for WBS24 by setting the IP assignment, Netmask and Gateway. These settings should be compatible with the Intranet since the network configu- ration setting is essential for data service. In addition, the RF frequency for WBS24 should be se- lected. Currently up to 14 frequencies may be selected.
Session Initiation Protocol(SIP) variables used for the WBS24(Basic) can be defined.
WLAN PARAMETER
No | Parameter | Description | Default |
05 | CODEC LIST | CODEC that can be used for VoIP calls between | CODEC 1: G.729 |
|
| WBS24 and terminal. G.711u, G.711a, G.726, and | CODEC 2: NONE |
|
| G.729 can all be assigned. | CODEC 3: NONE |
|
|
| CODEC 4: NONE |
06 | RF CHANNEL | Set a RF CHANNEL value that can be used by | USE CH 1: 01 |
|
| WBS. | USE CH 2: 06 |
|
|
| USE CH 3: 11 |
|
|
| USE CH 4: 00 |
|
|
| USE CH 5: 00 |
|
|
| USE CH 6: 00 |
|
|
|
|