OfficeServ 7100 Call Server Programming Guide

 

 

 

 

 

 

 

 

 

 

(continued)

 

 

 

 

 

 

 

No

Code

Alarm Name

Definition

 

 

-

MJD--

DTRK Error

ISDN or E1 card Fault

 

50

MJD18

E1 Restart

The E1 card has restarted.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

51

MJD19

PRI Restart

The PRI card has restarted.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

52

MJD20

BRI Restart

The BRI card has restarted.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

53

MJD21

PCM Loss

Loss of PCM coding on a digital facility.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

54

MJD22

PCM Recovery

Loss of PCM coding on a digital facility.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

 

-

MJE--

MGI Error

MGI card Fault

 

55

MJE01

MGI Restart

The MGI card has restarted.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

56

MJE02

MGI Stop

The MGI card has stoped.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

57

MJE03

MGI IP Duplicate

The MGI card IP address is duplicated.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

58

MJE04

MGI NTWK Error

The MGI card has blocked because the system detects

 

 

 

 

the card doesn’t respond via network link.

 

 

 

 

External ping test.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

59

MJE05

MGI NTWK Rec

The MGI card has restarted because the system detects

 

 

 

 

the card does respond via network link.

 

 

 

 

External ping test.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

60

MJE06

MGI DSP Error

The MGI card DSP has blocked because the system

 

 

 

 

detects the card DSP does not run correctly.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy-Pzz)

 

 

 

 

 

 

61

MJE07

MGI DSP Run

The MGI card DSP has restarted because the system

 

 

 

 

detects the card DSP runs correctly.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy-Pzz)

 

 

 

 

 

 

62

MJE08

WBS Disconnect

Indicates the WBS is disconnected.

 

 

 

 

Alarm Data = CWBS:xx or BWBS:xx

 

 

 

 

 

 

63

MJE09

WBS connect

Indicates the WBS is connected.

 

 

 

 

Alarm Data = CWBS:xx or BWBS:xx

 

 

 

 

 

 