[409] TRUNK STATUS READ

This is a READ-ONLY MMC. Allows the status of trunks to be read in a format that will enable the servicing personnel to quickly identify the ownership and position of a trunk.

No

Type

Description

00

PORT

Port Number(Cabinet/Slot/Port)

 

 

 

01

TYPE

LOOP, GND, E & M, DID, BRI, PRI, VOIP

 

 

 

02

1A2 EMULATE

1A2 Emulation On/Off

 

 

 

03

TRK FORWARD

Trunk Forward On/Off

04

LINE

CO/PBX

 

 

 

05

DIAL

DTFM/Dial Pulse

 

 

 

06-11

TOLL TYPE 1-6

Ring Plan Toll Restriction(1-6)

 

 

 

12-17

RING PLAN 1-6

Ring Plan Ring Destination(1-6)

 

 

 

18

MOH SOURCE

MOH Source

 

 

 

19

DISA LINE

DISA Status

 

 

 

DEFAULT DATA

FOLLOWS TRUNK

ACTION

 

 

DISPLAY

1)

Press Transfer button and enter 409.

 

 

[701]

TRK STATUS

 

Display shows:

PORT:C1-S5-P01

2)

Enter trunk number via dial keypad.(e.g., 704)

 

 

[704]

TRK STATUS

 

OR

PORT:C1-S5-P04

 

Press Volume button to make selection and press

 

 

 

Right Soft button to advance cursor.

 

 

3)

Enter desired option 00-19.(e.g., 01)

 

 

[704]

TRK STATUS

 

OR

TYPE:LOOP TRUNK

 

Press Volume button to make selection.

 

 

4)Press Transfer button to save and exit.

OR

Press Speaker button to advance to next MMC.