CHAPTER 2. Ошибка! Стиль не определен.
2-44 Samsung Business Communications
[200] OPEN CUSTOMER PROGRAMMING
Used to open(enable) and close(disable) customer-level programming. If programming is
not opened and an attempt is made to access a system MMC, the error message [NOT
PERMIT] will be displayed. A four digits passcode is required to access this MMC. Each
digit can be 0-9. When opened, this MMC enables access to all MMCs allowed in MMC
802, Customer Access MMC Number.
No Mode Description
0 DISABLE Open(enable) customer-level programming.
1 ENABLE Close(disable) customer-level programming.
DEFAULT DATA
DISABLE
ACTION DISPLAY
1) Press Transfer button and enter 200.
Display shows: ENABLE CUS.PROG.
PASSCODE:
2) Enter passcode. ENABLE CUS.PROG.
PASSCODE:
Correct code shows. ENABLE CUS.PROG.
DISABLE
Incorrect code shows. ENABLE CUS.PROG.
PASSCODE ERROR
3) Press Volume button arrow key to select ENABLE
or DISABLE and press Right Soft button. ENABLE CUS.PROG.
ENABLE
OR
Dial 1 for ENABLE or 0 for DISABLE.
4) Press Speaker button to advance MMC entry level
and press Volume button to select MMC. 201:CUS.PASSCODE
SELECT PROG. ID
OR
Enter MMC number and press Right Soft button
to enter MMC.
5) Press Transfer button to exit.
RELATED ITEMS
MMC 201 CHANGE CUSTOMER PASSCODE
MMC 501 SYSTEM-WIDE TIMERS
MMC 802 CUSTOMER ACCESS MMC NUMBER