OfficeServ 7100 Call Server Programming Guide

[503] TRUNK-WIDE TIMERS

Allows certain trunk timer values to be changed on a per-trunk basis or for all trunks.

No

Item

Description

Range

00

ANS.BAK TM

ANSWER BACK TIME. This timer is used for certain

0-2500 MSEC

 

 

types of E & M signalling and does not affect normal

 

 

 

CO lines.

 

 

 

 

 

01

CLEARING

This timer ensures that a call is fully disconnected at

100-9900 MSEC

 

 

the CO by preventing CO access outgoing or receiv-

 

 

 

ing incoming ring between a disconnect and the

 

 

 

expiration of this timer.

 

 

 

 

 

02

CO SUPV TM

CO SUPERVISION TIME. this is the minimum

10-2500 MSEC

 

 

length of loop open disconnect received from the

 

 

 

CO that will be seen as a valid hang up on the sys-

 

 

 

tem.

 

03

DTMF DUR.

DTMF DURATION. This is the length of the DTMF

100-9900 MSEC

 

 

digits that will be sent to the CO on this line.

 

04

F-DGT DELY

First-DIGIT DELAY. This is the length of time the

100-9900 MSEC

 

 

system will wait for CO line conditions to stabilize

 

 

 

after seizure before sending DTMF digits.

 

 

 

 

 

05

FLASH TIME

This is the duration of the momentary open sent on

20-2500 MSEC

 

 

a circuit when FLASH key is pressed.

 

 

 

 

 

06

NO RING TM

This is the length of time the system will wait after

1-25 SEC

 

 

detecting a ring burst on a line before deciding the

 

 

 

call has disconnected.

 

07

PAUSE TIME

This is the length of time the system will wait before

1-25 SEC

 

 

sending the next digit for a pause in a speed dial

 

 

 

bin.

 

 

 

 

 

08

PRS DET TM

This means the duration of PRS signal pulse. If the

0-2500 MSEC

 

 

PRS signal is reversed when opposite party is an-

 

 

 

swered and maintain the status before the opposite

 

 

 

party disconnect the call, the PRS DET TM must be

 

 

 

set to 0.

 

 

 

 

 

09

RNG DET TM

RING DETECT TIME. This is the minimum length of

10-2500 MSEC

 

 

ring signal the system will regard as a valid ring.

 

 

 

 

 

10

WINK TIME

This is the duration of the acknowledgment signal

100-300 MSEC

 

 

that the system will send on an E&M circuit

 

 

 

 

 

11

MF/DP INT

This is the interval between sending digit. In case of

100-9900 MSEC

 

 

DTMF signal, over the 500ms will be serviced as

 

 

 

100 ms.

 

12

MFR DLY TM

This is a delay time to allocate the MFR after incom-

0-25 SEC

 

 

ing trunk is detected. This is to prevent the wrong

 

 

 

detection of DTMF signal by noise.

 

 

 

 

 

Samsung Business Communications

2-149

Page 193
Image 193
Samsung 7100 manual TRUNK-WIDE Timers, Description Range