OfficeServ 7100 Call Server Programming Guide

 

 

 

 

 

 

 

 

 

 

(continued)

 

 

 

 

 

 

 

No

Code

Alarm Name

Definition

 

 

-

MJB--

LCP/TASK Error

LCP or TASK Fault

 

08

MJB01

HDLC Com Error

Communications to LCP lost or faulty.

 

 

 

 

 

 

09

MJB02

Memory Alarm 1

A RAM diagnostic check error has occurred in the

 

 

 

 

MCP2.

 

 

 

 

 

 

10

MJB03

Memory Alarm 2

A RAM diagnostic check error has occurred in cabinet 1

 

 

 

 

SCP2.

 

 

 

 

 

 

11

MJB04

Memory Alarm 3

A RAM diagnostic check error has occurred in cabinet 2

 

 

 

 

LCP2.

 

12

MJB05

Memory Alarm 4

A RAM diagnostic check error has occurred in cabinet 3

 

 

 

 

LCP2.

 

13

MJB06

IPC MSGQ Over

IPC TX queue full error has occurred in the MCP2.

 

 

 

 

Alarm data = IPC Queue type

 

 

 

 

(MCP-LAN, MCP-SCP, MCP-LCP1, MCP-LCP2)

 

 

 

 

 

 

14

MJB07

Task MSGQ Over

Task MSG queue full error has occurred in the MCP2.

 

 

 

 

Alarm data = Error Task

 

 

 

MJC--

DSP Error

System DSP Fault

16

MJC01

DTMF Fault

An abnormal interrupt has occurred in the system

 

 

 

 

DTMF resources.

 

 

 

 

Alarm data = DTMF Receiver DSP position

 

 

 

 

 

 

17

MJC02

Tone Fault

An abnormal interrupt has occurred in the system

 

 

 

 

tone resources.

 

 

 

 

Alarm data = TONE Receiver DSP position.

 

25

MJC10

AA-DTMF Fault

An abnormal fault reported in one of the AA card

 

 

 

 

DTMF resources.

 

 

 

 

Alarm data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

 

 

 

 

 

26

MJC11

AA-MFR Rec

An abnormal fault reported in one of the AA card

 

 

 

 

DTMF resources has recovered.

 

 

 

 

Alarm data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

27

MJC12

E911 Restart

The E911 card has restarted.

 

 

 

 

Alarm data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

28

MJC13

E911 Block

The E911 card has blocked because the system

 

 

 

 

detects the card does not work correctly.

 

 

 

 

Alarm data = Cabinet, Slot(Cx-Syy)

 

31

MJC16

WLI Restart

The WLI card has restarted.

 

 

 

 

Alarm data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

32

MJC17

WLI Block

The WLI card has blocked because the system

 

 

 

 

detects the card does not work correctly.

 

 

 

 

Alarm data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

Samsung Business Communications