OfficeServ 7100 Call Server Programming Guide

 

 

 

 

 

 

 

 

 

 

(continued)

 

 

 

 

 

 

 

No

Code

Alarm Name

Definition

 

 

80

MNF17

PSU Alarm Rec

Over-configuration of cabinet has been corrected.

 

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

81

MNF18

SLI Fault

An SLI card has been detected as out of service via an

 

 

 

 

internal CODEC test.

 

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

82

MNF19

SLI Recovery

An SLI card detected as out of service has been de-

 

 

 

 

tected as recovered and is in service via internal CO-

 

 

 

 

DEC test.

 

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

83

MNF20

PSUB Alarm

Indicates there are over 120 ports in a cabinet with two

 

 

 

 

PSUs.

 

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

 

 

84

MNF21

DSS Alarm

System capacity of 64-button DSS modules has been

 

 

 

 

exceeded.

 

85

MNF26

SIO RxQ Over

SIO Tx Queue full error has occurred in the MCP2.

 

 

 

 

Alarm Data = SIO number(SIO: x)

 

 

 

 

 

 

86

MNF27

SIO RxQ Under

SIO Tx Queue under error has occurred in the MCP2.

 

 

 

 

Alarm Data = SIO number(SIO: x)

 

 

 

 

 

 

87

MNF28

LAN Printer Err

LAN printer error has occurred in the MCP2.

 

 

 

 

Alarm Data = Data Type(SMDR)

 

 

 

 

 

 

88

MNF29

LAN Printer Rec

LAN printer error has recovered in the MCP2.

 

 

 

 

Alarm Data = Data Type(SMDR)

 

 

 

MNG--

Minor Error

Minor Fault without Alarm Buffer saving

 

 

 

 

 

 

89

MNG01

Phone Discon-

Indicates the Phone is disconnected.

 

 

 

nect

Alarm Data = Tel number or Cx-Syy-Pzz

 

90

MNG02

Phone Connect

Indicates the Phone is connected.

 

 

 

 

Alarm Data = Tel number or Cx-Syy-Pzz

 

 

 

 

 

 

91

MNG03

Off Hook Alarm

Indicates Extension Off Hook Alarm timer has expired.

 

 

 

 

Alarm Data = Tel number or Cx-Syy-Pzz

 

 

 

 

 

 

92

MNG04

On Hook

Indicates the Off Hook Alarm Extension is on hook.

 

 

 

 

Alarm Data = Tel number or Cx-Syy-Pzz

 

 

 

 

 

 

93

MNG05

MGI Packet Loss

Indicates the MGI connection RTP packet loss is more

 

 

 

 

than 10 %.

 

 

 

 

Alarm Data = Tel number or Cx-Syy-Pzz

 

 

 

 

 

 

94

MNG06

MGI Packet Delay

Indicates the MGI connection RTP packet delay is more

 

 

 

 

than 500 ms.

 

 

 

 

Alarm Data = Tel number or Cx-Syy-Pzz

Samsung Business Communications

2-343

Page 387
Image 387
Samsung 7100 manual Minor Error Minor Fault without Alarm Buffer saving