OfficeServ 7100 Call Server Programming Guide

[835] MGI DSP OPTIONS

This MMC provides various MGI DSP options.

No

Parameter

Description

Default

00

CODEC-FRAME

Selects which audio CODEC compression will be used

G.729A –

 

 

and the transmission interval time of VoIP packets gen-

20 Ms

 

 

erated by the MGI card. MGI3 card supports

 

 

 

G.729A(8 K), G.729(8 K), G.711(64 K), and

 

 

 

G.723.1(5.3~6.4K).

 

 

 

 

 

01

ECHO CANCEL

Enables or disables echo cancellation. This function

ENABLE

 

 

removes the echo that is generated by voice reflection

 

 

 

and packet delay.

 

 

 

 

 

02

SILENCE SUP

This parameter determines whether silence suppression

DISABLE

 

 

is used. This prevents transmission during the silence

 

 

 

period of a call, and conserves bandwidth when en-

 

 

 

abled.

 

 

 

 

 

03

IN FILTER

This option selects input filtering of the DSP. This should

ENABLE

 

 

always be set to ENABLE.

 

04

OUT FILTER

This option selects output filtering of the DSP. This

ENABLE

 

 

should always be set to ENABLE.

 

 

 

 

 

05

INPUT GAIN

PCM input gain value of DSP. The range is-

32

 

 

31 dB~32 dB(0~63).

 

 

 

This set the quality of PCM voice from the VoIP DSP to

 

 

 

the site. Default is 32(0 dB).

 

 

 

 

 

06

VOICE VOL

This value selects the voice volume. The range is-

32(0 dB).

 

 

31 dB~31 dB(0~63).

 

 

 

 

 

08

JITTER OPT

This is a scale value that introduces a intentional

4

 

 

buffer(delay) of the transmission of VoIP packets gener-

 

 

 

ated by the MGI card. This value determines whether

 

 

 

the focus is on packet loss or packet delay.

 

 

 

The range is 00~12.

 

 

 

 

 

09

MIN JITTER

Decides the minimum time to consider delay for jitter

30 ms

 

 

adjustment.

 

 

 

The range is 010~300 ms

 

 

 

 

 

10

MAX JITTER

Decides the maximum time to consider delay for jitter

150 ms

 

 

adjustment.

 

 

 

The range is 010-300 ms.

 

11

FAX ECM

This option selects retry of Fax-over-IP if errors are de-

ENABLE

 

 

tected.

 

 

 

 

 

12

MAX FAX CNT

This is the maximum number of channels that can be

2

 

 

simultaneously used for Fax-over-IP. The range is

 

 

 

00~16.

 

 

 

 

 

Samsung Business Communications