OfficeServ 7100 Call Server Programming Guide

(continued)

No

Parameter

Description

Default

14

PROVISIONAL

After receiving the Provision Response, the User Agent

180000 m

 

TIME

waits for this length of time until Timeout ends. The range

 

 

 

is 0~999900 ms.

 

 

 

 

 

15

INV.NO RESP

Before sending Cancel for the Invite Request, the User

5000 ms

 

TIME

Agent waits for this length of time. The range is

 

 

 

0~99900 ms.

 

 

 

 

 

16

GEN.NO

Before sending Cancel for General Request, the User

5000 ms

 

RESP TIME

Agent waits for this length of time. The range is

 

 

 

0~99900 ms.

 

 

 

 

 

17

REQ.RETRY

After sending General Request, the User Agent waits for

5000 ms

 

TIME

the Final Response for this length of time. The range is

 

 

 

0~99900 ms.

 

18

SIP SERVER

Sets ENABLE or DISABLE to use an optional, external

DISABLE

 

ENABLE

industry-standard SIP Server.

 

 

 

 

 

20

SIP SERVER

Sets SIP server IP address.

0.0.0.0.

 

IP

 

 

 

 

 

 

28

SIP SERVER

Sets the port to use on the SIP Server.

5060

 

PORT

 

 

 

 

 

 

29

SIGNAL PORT

Indicates the port number for SIP signalling and sets a

10000

 

 

range of numbers allowed by firewall equipment. The

 

 

 

common and default IP path or port used is 10000.

 

 

 

 

 

32

SEND CLIP

Refers to SEND CLI NUMBER(MMC 323), which pro-

1

 

TABLE

vides calling party identification when using the MGI as a

 

 

 

SIP gateway.

 

 

 

This provides station ID of the calling station. A single-

 

 

 

digit value corresponding to the desired table in MMC

 

 

 

323 should be entered here. This is only used when

 

 

 

MMC 405 value is null.

 

 

 

 

 

33

INCOMING

This option selects how incoming calls are routed when

FOLLOW DID

 

MODE

the MGI is used as a SIP gateway.

TRANS

 

 

0 FOLLOW TRUNK RING: Follows MMC 406

 

 

 

1 FOLLOW DID TRANS: Follows MMC 714(default)

 

 

 

2 FOLLOW INCOM DGT: Follows MMC 724

 

 

 

 

 

34

ALLOW GW

When using a gatekeeper, this permits the SIP gateway

DISABLE

 

CHECK

to check for gatekeeper presence.

 

35

REGIST T-GW

System number when registering as a trunking gateway.

4100

 

NUM

 

 

36

REGIST S-GW

System number when registering as a gateway for sta-

4200

 

NUM

tions.

 

 

 

 

 

37

CLIR WITH

When this option is enabled, the CLIP number is sent to

DISABLE

 

NUMBER

the network even if the CLIP restriction flag is set.

 

 

 

 

 

Samsung Business Communications