CHAPTER 2. Ошибка! Стиль не определен.
|
|
| (continued) |
|
|
|
|
No | Code | Alarm Name | Definition |
- |
| DTRK Error | ISDN or E1 card Fault |
33 | MJD01 | Sync Failure | Clocking on TEPRI cards has become asynchronous. |
|
|
|
|
34 | MJD02 | Sync Recovery | Clocking on TEPRI cards has become synchronous. |
|
|
|
|
35 | MJD03 | Red Alarm | Locally detected loss of PCM carrier on TEPRI card for |
|
|
| more than 250 ms. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
36 | MJD04 | Red Alarm Rec | PCM carrier detected locally on TEPRI cards. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
37 | MJD05 | Yellow Alarm | Remotely detected failure transmitted in frame on |
|
|
| TEPRI card. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
38 | MJD06 | Yellow Alarm | Remotely detected failure restored transmitted on |
|
| Rec | TEPRI card. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
39 | MJD07 | Blue Alarm | All 1's being transmitted on facility on TEPRI card. |
|
|
| Alarm Data = Cabinet, |
40 | MJD08 | Blue Alarm Rec | A blue alarm condition has been cleared. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
41 | MJD09 | Bit Error Alarm | Alarm is activated when the error rate exceeds 1 x |
|
|
| errors. Note: |
|
|
| threshold for major alarm errors on E1, PRI or BRI. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
42 | MJD10 | NTWRK Event | An Implausible event has occurred on the PRI or BRI |
|
|
| Network digital line. Protocols do not match or sub- |
|
|
| scriber ID mismatch. |
|
|
| Alarm Data = Cabinet, |
|
|
|
|
43 | MJD11 | SPID Init Error | The BRI received an error from the network. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
44 | MJD12 | SPID Init Rec | The BRI has recovered from an error on the network |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
45 | MJD13 | LPBK Error | Internal on demand loopback failed. |
|
|
| Alarm Data = Cabinet, Slot, |
46 | MJD14 | LPBK Recovery | Internal on demand loopback test passed. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
47 | MJD15 | BRI DL Unavail | A BRI data link is out of service. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
48 | MJD16 | BRI DL Recovery | A BRI data link is back in service. |
|
|
| Alarm Data = Cabinet, Slot, |
|
|
|
|
49 | MJD17 | RAM Error | An error has occurred in the TEPRI or BRI card RAM. |
|
|
| Alarm Data = Cabinet, |
Samsung Business Communications |