CHAPTER 2. Ошибка! Стиль не определен.

 

 

 

(continued)

 

 

 

 

No

Code

Alarm Name

Definition

-

MJD--

DTRK Error

ISDN or E1 card Fault

33

MJD01

Sync Failure

Clocking on TEPRI cards has become asynchronous.

 

 

 

 

34

MJD02

Sync Recovery

Clocking on TEPRI cards has become synchronous.

 

 

 

 

35

MJD03

Red Alarm

Locally detected loss of PCM carrier on TEPRI card for

 

 

 

more than 250 ms.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

36

MJD04

Red Alarm Rec

PCM carrier detected locally on TEPRI cards.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

37

MJD05

Yellow Alarm

Remotely detected failure transmitted in frame on

 

 

 

TEPRI card.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

38

MJD06

Yellow Alarm

Remotely detected failure restored transmitted on

 

 

Rec

TEPRI card.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

39

MJD07

Blue Alarm

All 1's being transmitted on facility on TEPRI card.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

40

MJD08

Blue Alarm Rec

A blue alarm condition has been cleared.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

41

MJD09

Bit Error Alarm

Alarm is activated when the error rate exceeds 1 x 10-6

 

 

 

errors. Note: 1x10-6is threshold for minor alarm, 1 x 10-3is

 

 

 

threshold for major alarm errors on E1, PRI or BRI.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

42

MJD10

NTWRK Event

An Implausible event has occurred on the PRI or BRI

 

 

 

Network digital line. Protocols do not match or sub-

 

 

 

scriber ID mismatch.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

43

MJD11

SPID Init Error

The BRI received an error from the network.

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

 

 

 

 

44

MJD12

SPID Init Rec

The BRI has recovered from an error on the network

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

 

 

 

 

45

MJD13

LPBK Error

Internal on demand loopback failed.

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

46

MJD14

LPBK Recovery

Internal on demand loopback test passed.

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

 

 

 

 

47

MJD15

BRI DL Unavail

A BRI data link is out of service.

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

 

 

 

 

48

MJD16

BRI DL Recovery

A BRI data link is back in service.

 

 

 

Alarm Data = Cabinet, Slot, Channel(Cx-Syy-czz)

 

 

 

 

49

MJD17

RAM Error

An error has occurred in the TEPRI or BRI card RAM.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

2-340

Samsung Business Communications

Page 384
Image 384
Samsung 7100 manual Dtrk Error Isdn or E1 card Fault