OfficeServ 7100 Call Server Programming Guide

[759] CLI RINGING

This MMC assigns a specific CID number received from the central office to a specific ring plan destination. Also allows you to reject a specific CID number and assign priorities. There are 9 priority levels: priority 1 is the highest and priority 9 is the lowest.

It also allows you to select the ring tone heard at a phone when called by a specific CID number. There is also a cadence control option to perform a similar function for SLTs. There are eight ring tones available along with a Follow Station(NO) option. There are five cadences and a Follow Station option(NO) for SLTs. The CID Ringing table consists of 100 entries.

DEFAULT DATA

NONE

 

Option

 

 

Description

 

CLI

CID number to be received from the central office. Up to 16 digits may be

 

 

entered.

 

REJ

CID call reject option. When this sets YES, if a call comes that matched CID

 

 

number and CLI field then the system will be reject call.

 

PRI

CID priority option. There are 9 priority levels: priority 1 is the highest and

 

 

priority 9 is the lowest. When calls into station group come and group mem-

 

 

bers are all busy, the system will assign a priority to the CID number so that

 

 

calls from a high priority CID number will be placed at the front of the group

 

 

queue.

 

 

 

If this option sets NO, the longest call that placed at the group queue has

 

 

the highest priority.

 

R1: XXX, R2: XXX,

Ring plan and destination during each ring plan. The destination can be a

 

R3: XXX, R4: XXX,

station, station group.

 

R5: XXX, R6: XXX

 

 

 

 

TONE

Ring Tone options for a specific CID Number.(NO, 1~8)

 

 

No

 

Calls will ring with the phone users choice of ring frequency.

 

 

1~8

 

Calls from the programmed CID number will ring phones with this

 

 

 

 

ring frequency.

 

CAD

Ring Cadence options for a specific CID Number at SLT’s(NO, 1~5)

 

 

 

 

 

 

No

 

Calls will ring with the normal SLT ring cadences.

 

 

1

 

Calls from the programmed CID number will ring SLT’s with the intercom

 

 

 

 

ring cadence.

 

 

 

 

 

 

 

2

 

Calls from the programmed CID number will ring SLT’s with the CO ring

 

 

 

 

cadence.

 

 

 

 

 

 

 

3

 

Calls from the programmed CID number will ring SLT’s with the DOOR

 

 

 

 

ring cadence.

 

 

 

 

 

 

 

4

 

Calls from the programmed CID number will ring SLT’s with the ALARM

 

 

 

 

ring cadence.

 

 

 

 

 

 

 

5

 

Calls from the programmed CID number will ring SLT’s with the CALL-

 

 

 

 

BACK ring cadence.

 

 

 

 

 