CHAPTER 2. Ошибка! Стиль не определен.

 

 

 

(continued)

 

 

 

 

No

Code

Alarm Name

Definition

 

MNF--

Minor Error

Minor Fault with Alarm Buffer saving

64

MNF01

Card Out

A circuit card mounted in a universal slot has been re-

 

 

 

moved from service or is not recognized by the system.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

65

MNF02

Card In

A circuit card mounted in a universal slot has been re-

 

 

 

turned to service.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

66

MNF03

IPC Error

Inter-processor communication error has occurred.

 

 

 

Alarm Data = Cabinet-Slot(Cx-Syy)

 

 

 

 

67

MNF04

Trunk Fault

Out of service trunk detected via loop detect. Internal

 

 

 

CODEC test.

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

 

 

 

68

MNF05

Trunk Recovery

Out of service trunk detected via loop detected as out of

 

 

 

service is now operational.

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

69

MNF06

Trunk Discon-

Out of service trunk detected via seizure of trunk. Exter-

 

 

nect

nal seizure test.

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

 

 

 

 

70

MNF07

Trunk Connect

Out of service trunk recovered via seizure of trunk. Ex-

 

 

 

ternal seizure test.

 

 

 

Alarm Data = Cabinet, Slot, Port(Cx-Syy-Pzz)

71

MNF08

SIO TxQ Over

SIO Tx Queue full error has occurred in the MCP2.

 

 

 

Alarm Data = SIO number(SIO: x)

 

 

 

 

72

MNF09

SIO TxQ Under

SIO Tx Queue under error has occurred in the MCP2.

 

 

 

Alarm Data = SIO number(SIO: x)

 

 

 

 

73

MNF10

E1 Out Of Srv

E1 Digital line status has been changed to out of ser-

 

 

 

vice.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

74

MNF11

E1 In Service

E1 Digital line has been restored to normal service.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

75

MNF12

SIO Out

IO port has lost DTR.

 

 

 

Alarm Data = SIO number(SIO: x)

 

 

 

 

76

MNF13

SIO In

IO port has regained DTR.

 

 

 

Alarm Data = SIO 1 through 6

77

MNF14

TODC Error

Time of Day Clock in the MCP2 has erred.

78

MNF15

TSW Over Alarm

The TSW has been requested to exceed the capacity of

 

 

 

available time slots. Maximum 192 per cabinet.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

 

 

 

 

79

MNF16

PSU Alarm

There are more ports than can be supported in a

 

 

 

cabinet and more power is required.

 

 

 

Alarm Data = Cabinet, Slot(Cx-Syy)

2-342