OfficeServ 7100 Call Server Programming Guide

[502] STATION-WIDE TIMERS

Allows certain station timer values to be changed on a per-station basis or for all stations.

No

Item

Description

0

NO ANS FWD

This timer controls how long the station will ring before Forward on No

 

 

Answer takes place.(1-250 sec)

 

 

 

1

DTMF DUR.

This timer governs the duration of DTMF digits which are transmitted to

 

 

an external VMS system port. This can be used when a VMS system fails

 

 

to recognise the default DTMF digit duration being transmitted from the

 

 

SLT port.(100-9900 ms)

2

F-DGT DELY

This timer will be valuable for the system administrator to insert a suitable

 

 

delay before generating DTMF digits for In-Band integration.(100-

 

 

9900 ms)

 

 

 

3

OFFHK SEL.

This timer controls the grace period before placing an internal/external call

 

 

as programmed in MMC 306.(0-250 sec)

4

EFWD DELAY

This timer controls the External Call Forward feature which will allow a

 

 

station to ring before the call is placed on external call forwarding.

 

 

(1-250 sec)

 

 

 

5

CC RNG DLY

If a station does not answer an incoming call within this time, other sta-

 

 

tions with a CC key for that station will ring.

 

 

 

CONDITIONS

NONE

DEFAULT DATA

NO ANS FWD: 015 SEC

DTMF DUR: 100 MSEC

F-DGT DELY: 600 MSEC

OFFHK SEL: 008 SEC

EFWD DELAY: 010 SEC

CC RNG DLY: 010 SEC

Samsung Business Communications

2-147

Page 191
Image 191
Samsung 7100 manual STATION-WIDE Timers