OfficeServ 7100 Call Server Programming Guide

[501] SYSTEM TIMERS

Allows the technician to adjust individual timers as necessary.

TIMER TABLE

Timer Name

Default

Range Unit

Description

ALARM TIME

100

0-2500 MIN

This is the time the system alarm key will start

 

 

 

ringing after the alarm key has been silenced.

 

 

 

 

ALERT TONE TIME

1000

100-2500

This timer sets the duration of the attention

 

 

MSEC

tone preceding a call to a phone in the Voice

 

 

 

Announce or Auto Answer mode. This tone

 

 

 

will also precede a forced Auto Answer call.

 

 

 

 

ALM REM.INTERVAL

25

1-250 SEC

This timer controls the time between ring at-

 

 

 

tempts at a station when alarm reminder is

 

 

 

set.

ALM REM RING OFF

10

1-25 SEC

This timer controls the length of the ring cycle

 

 

 

duration when an alarm reminder is set at a

 

 

 

station.

 

 

 

 

ATT. RECALL TIME

30

0-250 SEC

This controls how long a transfer recall will

 

 

 

ring at a station before recalling the operator.

AUTO REDIAL INT.

30

1-250 SEC

This timer controls the time between attempts

 

 

 

after RETRY dialling is set on a station.

 

 

 

 

AUTO REDIAL RLS.

45

1-250 SEC

This timer controls the duration of a Ring No

 

 

 

Answer condition on a retry number dialled

 

 

 

before the auto redial is automatically can-

 

 

 

celled.

BOOTH TIME OUT

005

0-250 MIN

Controls the time for which a booth phone is

(Hotel application only)

 

 

enabled.

 

 

 

 

CALLBACK NO ANS

30

1-250 SEC

This timer controls the time before the call-

 

 

 

back is automatically cancelled when a call-

 

 

 

back detects Ring No Answer.

CAMP ON RECALL

30

0-250 SEC

This timer controls the time a camped-on call

 

 

 

will stay at a destination before recalling to the

 

 

 

transferring station.

 

 

 

 

CID MSG RECEIVE

6

1-25 SEC

The amount of time that the system will allow

 

 

 

a valid message from the analogue CID trunk.

CLI DISPLAY TIME

5

1-25 SEC

The amount of time that the Caller ID informa-

 

 

 

tion remains on the phone’s display.

CO CLEAR TIME

30

0-250 SEC

The length of time a Direct Trunk Select key

 

 

 

remains busy after cleardown.

 

 

 

 

Samsung Business Communications

2-141

Page 185
Image 185
Samsung 7100 manual System Timers, Timer Name Default Range Unit Description