CHAPTER 2. Ошибка! Стиль не определен.

 

 

 

(continued)

 

 

 

 

Timer Name

Default

Range Unit

Description

CO CONFIRM TIME

3

0-250 MIN

According to MMC 314 CO CONFIRM type,

 

 

 

the outgoing call will be disconnected after

 

 

 

this timer expires or the outgoing caller will

 

 

 

hear the confirm tone.

 

 

 

 

CO-CO DISCONNECT

20

1-250 MIN

This timer monitors the duration of an unsu-

 

 

 

pervised conference; when it expires, both

 

 

 

trunks are disconnected.

CONFIRM TONE TM

1000

100-2500

The tone heard when a feature is activated or

 

 

MSEC

deactivated.

 

 

 

 

CRD TONE INT TM

30

0-250 SEC

This is the call record tone interval time. An entry

 

 

 

other than zero will cause a tone to be heard by

 

 

 

all the parties in a recorded conversation. The

 

 

 

range for the tone is 001(every second) to 255

 

 

 

(every 255 seconds). A value of 000 means no

 

 

 

tone. Requires an SVMi card.

DIAL PASS TIME

3

0-25 SEC

This timer monitors the time before connect-

 

 

 

ing the transmit of the phone to the trunk side

 

 

 

of an outgoing call.

 

 

 

 

DISA DISCONNECT

30

1-250 MIN

This timer controls the maximum duration of a

 

 

 

DISA call.

DISA LOCK OUT TM

30

1-250 MIN

This timer controls how long a DISA call is not

 

 

 

allowed to be made after the DISA error

 

 

 

counter has expired(MMC 500).

 

 

 

 

DISA NOANS DISC.

30

0-250 SEC

This timer determines when a DISA call is

 

 

 

disconnected by force when a called party

 

 

 

does not answer.

DISA PASS CHECK

30

1-250 MIN

This timer defines the period before the sys-

 

 

 

tem clears the incorrect passcode counter.

 

 

 

 

DISA NO ACTION

10

0-250 SEC

This timer controls how long a DISA line will

 

 

 

wait for further action from the caller.

 

 

 

 

DISPLAY DELAY TM

2

1-250 SEC

This timer controls how long a display is

 

 

 

shown in the LCD and how long error tone is

 

 

 

heard.

 

 

 

 

DOOR LOCK RELES.

500

100-2500

This timer controls how long the door lock

 

 

MSEC

relay will be activated.

 

 

 

 

DOOR RING DETECT

50

10-250

This timer controls the time before a call is

 

 

MSEC

answered by the door phone.

 

 

 

 

DOOR RING OFF TM

30

1-250 SEC

This timer controls the duration of ringing at

 

 

 

the door ring destination before automatically

 

 

 

cancelling.

 

 

 

 

E-HOLD RECALL TM

45

0-250 SEC

This timer controls how long a call is held ex-

 

 

 

clusively at a station before recalling.

 

 

 

 

2-142

Samsung Business Communications

Page 186
Image 186
Samsung 7100 manual CO Confirm Time, CO-CO Disconnect, Confirm Tone TM, CRD Tone INT TM, Dial Pass Time, Disa Disconnect