CHAPTER 2. Ошибка! Стиль не определен.
2-142 Samsung Business Communications
(continued)
Timer Name Default Range Unit Description
CO CONFIRM TIME 3 0-250 MIN According to MMC 314 CO CONFIRM type,
the outgoing call will be disconnected after
this timer expires or the outgoing caller will
hear the confirm tone.
CO-CO DISCONNECT 20 1-250 MIN This timer monitors the duration of an unsu-
pervised conference; when it expires, both
trunks are disconnected.
CONFIRM TONE TM 1000 100-2500
MSEC
The tone heard when a feature is activated or
deactivated.
CRD TONE INT TM 30 0-250 SEC This is the call record tone interval time. An entry
other than zero will cause a tone to be heard by
all the parties in a recorded conversation. The
range for the tone is 001(every second) to 255
(every 255 seconds). A value of 000 means no
tone. Requires an SVMi card.
DIAL PASS TIME 3 0-25 SEC This timer monitors the time before connect-
ing the transmit of the phone to the trunk side
of an outgoing call.
DISA DISCONNECT 30 1-25 0 MIN This timer controls the maximum duration of a
DISA call.
DISA LOCK OUT TM 30 1-250 MIN This timer controls how long a DISA call is not
allowed to be made after the DISA error
counter has expired(MMC 500).
DISA NOANS DISC. 30 0-250 SEC This timer determines when a DISA call is
disconnected by force when a called party
does not answer.
DISA PASS CHECK 30 1-250 MIN This timer defines the per iod before the sys-
tem clears the incorrect passcode counter.
DISA NO ACTION 10 0-250 SEC This timer controls how long a DISA line will
wait for further action from the caller.
DISPLAY DELAY TM 2 1-250 SEC This timer controls how long a display is
shown in the LCD and how long error tone is
heard.
DOOR LOCK RELES. 500 100-2500
MSEC
This timer controls how long the door lock
relay will be activated.
DOOR RING DETECT 50 10-250
MSEC
This timer controls the time before a call is
answered by the door phone.
DOOR RING OFF TM 30 1-250 SEC This timer controls the duration of ringing at
the door ring destination before automatically
cancelling.
E-HOLD RECALL TM 45 0-250 SEC This timer controls how long a call is held ex-
clusively at a station before recalling.