Samsung 7100 manual MSG Waiting Lamp Cadence, Interrupt LED 1000MS-ON 1000MS-OFF, Interrupted

Models: 7100

1 407
Download 407 pages 58.94 Kb
Page 205
Image 205

OfficeServ 7100 Call Server Programming Guide

[511] MSG WAITING LAMP CADENCE

This MMC defines the cadence(flash rate) of single line telephone message waiting lamps on phones connected to systems with an MWSLI card. There are two choices for the MW lamp cadence: continuous and interrupted.

No

Item

Description

0

INTERRUPTED

The MW lamp will flash at a rate determined by the timer settings.

 

 

The shortest ontime is 100 ms and the longest ontime is

 

 

3000 ms. The timer is adjusted in 100 ms increments.

 

 

 

1

CONTINUOUS

When an MWSLI port has a message, the lamp will be lit steady.

 

 

 

CONDITIONS

Systems with MWSLI cards only.

DEFAULT DATA

INTERRUPT LED: 1000MS-ON 1000MS-OFF

ACTION

 

 

DISPLAY

1)

Press Transfer button and enter 511.

 

MW LAMP CADENCE

 

Display shows:

INTERRUPT LED

2)

Press 0 or 1 to select CADENCE.

 

MW LAMP CADENCE

 

OR

INTERRUPT LED

 

Press Volume button to make selection.

 

 

 

Press Right Soft button to advance step 3.

 

 

3)

Dial new values for interrupt times.(four digits)

 

MW LAMP CADENCE

 

Press Right Soft button to move cursor back.

2000

2000

 

 

 

 

If valid entry, system returns to step 2.

 

 

Press Left Soft button to move cursor back.

If valid entry, system returns to step 2.

4)Press Transfer button to save and exit.

OR

Press Speaker button to save and advance to next MMC.

RELATED ITEMS

NONE

Samsung Business Communications

2-161

Page 205
Image 205