OfficeServ 7100 Call Server Programming Guide

 

 

 

 

 

 

 

 

 

 

(continued)

 

 

 

 

 

 

 

Timer Name

Default

Range Unit

Description

 

 

TRANSFER RECALL

20

0-250 SEC

This timer determines how long transferred

 

 

 

 

 

calls ring before recalling. This is a system-

 

 

 

 

wide timer.

 

 

 

 

 

 

 

TRK AUTOMOH DISC

60

1-250 SEC

When set to ON, incoming trunk calls are

 

 

 

 

connected to MOH automatically after the

 

 

 

 

DISA ANSWR timer(MMC 503) expires. In

 

 

 

 

this case the caller hears MOH. If the TRK

 

 

 

 

AUTOMOH DISC timer expires before the

 

 

 

 

call is answered, the call is disconnected.

 

 

 

 

 

 

 

TSW CONN. DELAY

0

0-10 SEC

When an incoming trunk makes an outgoing

 

 

 

 

call to another trunk, the system connects the

 

 

 

 

voice path after this time.

 

 

 

 

 

 

 

UCDS AUDIO ALARM

0

0-990 SEC

When an SVMi-20 card is installed and the digital

 

 

 

 

UCD package enabled, this counter determines

 

 

 

 

the maximum number of seconds a call has

 

 

 

 

been waiting at the UCD group before the UCD

 

 

 

 

group’s SUPV key begins to flash along with an

 

 

 

 

audio alarm. For more UCD alarm conditions,

 

 

 

 

see MMC 500.

 

 

 

 

 

 

 

UCDS VISUAL ALARM

0

0-250 SEC

When an SVMi-20 card is installed and the

 

 

 

 

digital UCD package enabled, this counter

 

 

 

 

determines the maximum number of seconds

 

 

 

 

a call at the UCD group before the UCD

 

 

 

 

group’s SUPV key begins to flash as an

 

 

 

 

alarm. For more UCD alarm conditions, see

 

 

 

 

MMC 500.

 

 

 

 

 

 

 

VOIP RE-ROUTE TM

15

0-25 SEC

If an outgoing call made via a VoIP trunk

 

 

 

 

does not receive an acknowledgement mes-

 

 

 

 

sage from the called party within this time,

 

 

 

 

the call is treated as failed.

 

 

 

 

 

 

When timers value is 0

Some timers are disabled when their value is set to 0.

DEFAULT DATA

SEE DESCRIPTION

SOME TIMERS DEPEND ON COUNTRY

Samsung Business Communications