OfficeServ 7100 Call Server Programming Guide

 

 

 

 

 

 

 

 

(continued)

 

 

 

 

 

 

No

Option

Description

 

 

5

NB PLAN

Used to select the type of the Calling Party Number Plan to send to the net-

 

 

 

 

work.

 

 

 

UNKNOWN

Unknown numbering plan

 

 

 

 

 

 

 

ISDN

ISDN numbering plan(CCITT E.163-164)

 

 

 

 

 

 

 

DATA

Data numbering plan(CCITT X.121)

 

 

 

 

 

 

 

TELEX

Telex numbering plan(CCITT F.69)

 

 

 

 

 

 

 

NATIONAL

National standard numbering plan

 

 

 

 

 

 

 

PRIVATE

Private numbering plan

 

 

 

 

 

 

 

EXTEN

Local numbering plan

 

 

 

 

 

OPTIONS FOR BRI PORTS PROGRAMMED AS STATIONS

 

 

 

 

 

No

Option

Description

 

 

0

ANY CHANNEL

When this option is set to YES, the system will place calls on any free

 

 

 

 

channel of that BRI if the channel chosen by the user is busy.(e.g., Pre-

 

 

 

ferred channel selection) If set to NO, the user will receive a busy signal

 

 

 

if they attempt to access a busy channel even if the other channel on

 

 

 

that BRI is free.(e.g., Exclusive channel selection)

 

 

 

 

 

1

POWER FEED

This field determines if power to a BRI access will be supplied.(YES or

 

 

 

NO)

 

 

 

 

 

CONDITIONS

yA BRI card must be installed in the system. Otherwise, the ‘NO BRI CARD’ message is displayed.

yIf any changes are made in this MMC, the BRI card that is affected by these changes MUST be restarted using MMC 418 in order for the changes to become effective.

DEFAULT DATA

For BRI Ports programmed as Trunks:

CHANNEL ANY: YES

BRI MODE: P-P DDI

DLSEND: OVERLAP

CLIP TABLE: NONE

NB TYPE: NATIONAL

NB PLAN: ISDN

For BRI Ports programmed as Stations:

CHANNEL ANY: YES

POWER FEED: NO