(12) Zero suppression

No. of zeros to be suppressed

0

1

2

2

3

4

5

 

 

 

 

 

 

 

 

Data

0000

0000

0000

0A12

0123

0123

0123

Print

0000

0

00

A12

123

0123

0123

The leading zero(s) in a data row is replaced by a space(s) according to the designated number of digits. However, if the number of digits to be suppressed is greater than the data row, the data row will be drawn without zero suppression. Where the data row exceeds the maximum number of digits (40), the data row will not be drawn.

When the print data including start/stop codes are sent to sending print data, the start/stop codes are also counted as a digit each. When the bar code type is JAN, EAN, UPC, or UCC/EAN 128, the data will be drawn without zero suppression.

(13)Data string to be printed

Drawing data can be programmed by designating the number of digits after the symbol “=.” The maximum number of digits to be printed varies according to the types of bar codes. For codes, refer chapter 13 “BAR CODE TABLE”.

(14)Link field No.

The link field No. can be programmed by designating it after the symbol “;.” After the link field No. is designated using the Format Command, the data string are linked by the Link Field Data Command to draw an image.

Up to 20 fields can be linked.

The following shows an example of linked fields on the two continuous labels.

[Format Command]

 

 

[ESC] PC01;

; 01 [LF] [NUL]

: Link field No. 1 is designated.

[ESC] PC02;

; 03 [LF] [NUL]

: Link field No. 3 is designated.

[ESC] PC03;

; 04 [LF] [NUL]

: Link field No. 4 is designated.

[ESC] XB01;

; 03, 04 [LF] [NUL]

: Link fields No. 3 and No. 4 are

 

 

designated.

[ESC] PC04;

; 02 [LF] [NUL]

: Link field No. 2 is designated.

[ESC] PC05;

; 03 [LF] [NUL]

: Link field No. 3 is designated.

[ESC] PC06;

; 04 [LF] [NUL]

: Link field No. 4 is designated.

[ESC] XB02;

; 03, 04 [LF] [NUL]

: Link fields No. 3 and No. 4 are

 

 

designated.