Qqrstuvw: Area lock designation (Effective only when the Hibiki tag is used for the B- SX704-RFID-U2-R.

Designates an area lock type.

Area lock type can be specified for up to eight areas continuously. For example: Q1100000,Q4101010,Q5100010, which indicates: Bank1:Read lock, Bank4:Read lock, Write lock, Password read/write lock Bank5:Read lock, Password read/write lock

q:Area bank designation (1 to 8)

1:Bank1 (EPCC/UII bank)

2:Bank2 (TID bank)

3:Bank3 (User area)

4:Bank4 (User block 1)

5:Bank5 (User block 2)

6:Bank6 (User block 3)

7:Bank7 (User block 4)

8:Bank8 (User block 5)

r:Read lock designation

0:Disabled

1:Enabled

s:Read permanent lock designation

0:Disabled

1:Enabled

t:Write lock designation (Effective to Bank4 to Bank8 only)

0:Disabled

1:Enabled

u:Write permanent lock designation (Effective to Bank4 to Bank8 only)

0:Disabled

1:Enabled

v:User block password read/write lock designation (Effective to Bank4 to Bank8 only)

0:Disabled

1:Enabled

w:User block password read/write permanent lock designation (Effective to Bank4 to Bank8 only)

0:Disabled

1:Enabled

NOTES:

1.Once a permanent lock is enabled for parameter s, u, or w, any subsequent change is disabled.

2.When read/write permanent lock is selected, a read/write lock state is retained. To permanently prohibit reading/writing a tag, enable both the read/write lock and the read/write permanent lock. The setting which disables the read/write lock and enables the read/write permanent lock allows the tag to be read/written permanently.