(5)Head Open Error
cIf the head open sensor detects the open state in 5 mm continuously, an error will result.
dIf the head open sensor detects the open state when an issue, a feed, or an ejection is attempted in a printer stop state, an error will result.
eIf the
fIf the
However, the feeding by the [FEED] key on the printer and the issuing and feeding by the expansion I/O are not included.
(6)Thermal Head Error
cA broken dot error has occurred in the thermal head. d An error has occurred in the thermal head driver.
(7)Thermal Head Excessive Temperature
cWhen the
dWhen the thermal head temperature detection thermistor detects an excessively high temperature (80 °C or more), an error will result.
eWhen the heat sink sensor detects an excessively high temperature (91 °C or more), an error will result.
(8)Ribbon Error
cWhen the ribbon rewind motor sensor and ribbon back tension motor sensor do not perform detection if twice the prescribed time has passed, an error will result.
•An abnormal condition has occurred in the sensor for determining the torque for the ribbon motor.
•A ribbon jam has occurred.
•The ribbon has run out.
•The ribbon has not been installed.
(9)Rewinder Overflow
cIf the rewinder overflow sensor detects the overflow state in 5 mm continuously when the strip function or the
dIf the overflow sensor detects an overflow state when an issue, a feed, or an ejection is attempted in a printer stop state after the strip function or the
*At the moment an error occurs, the printer shows the error message, makes a status response, and then stops. Only the Status Request Command and the Reset Command can be processed. Other commands are not processed. Restoration using the [RESTART] key is possible except in the case of a thermal head excessive temperature error. (The printer resumes printing a label at which the error had occurred.)