Boot program

V1.0

V1.1

V1.1A

V2.0

V2.0A

V2.0B

V2.0E

V3.0

Main program

 

 

 

 

 

 

 

 

V5.4

X

X

X

X

X

X

X

{

X5.4

X

X

X

X

X

X

X

{

V5.5

X

X

X

X

X

X

X

{

{: This combination enables the proper printer operation.

X: This combination disables the proper printer operation.

NOTES: 1. Some program versions are not released actually.

2.Boot programs V1.1A and V2.0A do not support the SNMP function as they are not able to download this function. Any other functions than the SNMP function are supported.

3.As the SNMP function has been included in the main program V5.0, it is not necessary to download the SNMP program. Even if it is downloaded by mistake or the printer is used with the SNMP program installed, there is no impact on the printer operation.

4.Firmware V5.0 or greater will not work with the MAIN3-R or earlier PC board. The MAIN4-R or greater is required. Be careful of the combination.

 

 

 

Main PC board

 

 

 

 

 

 

 

MAIN4-R or greater

 

MAIN3-R or earlier

 

 

 

 

 

Firmware

Boot

Downloaded normally.

 

When the boot program is sent to the

 

program

 

 

printer by the downloader, the printer

 

V3.0 or

 

 

shows “MODEL TYPE ERROR” on the

 

greater

 

 

LCD and results in an error.

 

 

 

 

When the COM is used as the

 

 

 

 

interface, the downloader shows

 

 

 

 

“Check Sum Error”. (Then, the printer

 

 

 

 

is forcibly shut down.)

 

 

 

 

After the printer is restarted, it starts

 

 

 

 

up in the previous status.

 

Main

Downloaded normally.

 

When the main program is sent to the

 

program

 

 

printer by the downloader, the printer

 

V5.0 or

 

 

erases the Flash ROM and shows

 

greater

 

 

“FORMAT ERROR” on the LCD.

 

 

 

 

When the COM or LPT1 is used as the

 

 

 

 

interface, the downloader shows

 

 

 

 

“Erase Error”. Then, the printer is

 

 

 

 

forcibly shut down.

 

 

 

 

After the printer restarted, it starts up

 

 

 

 

in the DOWNLOAD MODE.

 

 

 

 

Downloading the main program earlier

 

 

 

 

than V5.0 enables a recovery from the

 

 

 

 

erroneous state.

- 3 -