6.3.28 SAVED DATA CALL COMMAND (For Flash Memory)

[ESC] XQ

Function

Format

Term

Notes

Refer to

Examples

Calls PC interface commands saved in flash memory.

[ESC] XQ; aa, (Sb,) c, d [LF] [NUL]

aa:Identification number of the file to be called from the flash memory card 01 to 99

Sb: Drive from which the command is called

(Omissible. If omitted, flash ROM on the CPU board is selected.)

b:Drive

0:Flash ROM on the CPU board

1:Slot 1 on the PCMCIA board (Option)

2:Slot 2 on the PCMCIA board (Option)

c:Status response when the data is called up

0:No status response made

1:Status response made

d:Auto call at power on time

L:Auto call

M:No auto call

(1)If the relevant save identification number is not found, an error will result.

(2)However, if no save identification number subject to auto call is found with the option for auto call at power on time selected, the option for no auto call will be selected causing no error.

(3)If a command error is found in the PC interface command in auto call at power on time by the Saved Data Call Command, a command error will result. After an error has occurred, the power must be turned off. The option for no auto call is selected when the power is turned on again.

(4)The printer enters the online mode (label issue operation) when the Save Data Call Command is sent after the Save Terminate Command.

Save Start Command ([ESC] XO)

Save Terminate Command ([ESC] XP)

[ESC] XQ; 01, 0, L [LF] [NUL] [ESC] RC001; Sample [LF] [NUL]

[ESC] RC002; 100 [LF] [NUL]

[ESC] XS; I, 0002, 0002C3000 [LF] [NUL]

- 221 -

Page 225
Image 225
Toshiba B-SX4T-GS20-QM-R manual Esc Xq