Explanation

(1)The parameter, “Number of bytes to be read”, is effective only when RFID read mode is set to 1 or 3, as this parameter is intended for reading user data. When reading tag ID, this parameter is ignored.

(2)When the value exceeding the maximum number of bytes storable in a tag is designated for “Number of bytes to be read”, a read error results.

(3)With RFID (data read) being specified by this command, when an RFID data read failed, the printer will retry to read data after sending a void pattern printing end status (60H) or result in an error and stop after sending an RFID write error status (61H).

SOH

01H

Indicates the start of the status block

STX

02H

 

Status

34H

Printer status

32H

 

 

Status type

34H

Indicates the end of an RFID read and issue.

 

 

 

 

3XH

 

Remaining

3XH

Remaining issue count

count

3XH

 

 

3XH

 

 

 

30H30H: RFID read failed.

 

 

31H31H: I-Code

 

XXH

31H32H: Tag-it

 

31H33H: C220

 

 

 

 

31H34H: ISO15693

Tag type

 

31H35H: C210

 

31H36H: C240

 

 

 

 

31H37H: C320

 

XXH

32H31H: EPC Class 0

 

32H32H: EPC Class 1

 

 

 

 

32H33H: ISO18000-6B

 

 

32H34H: EPC Class 1 Generation 2

Length

XXH

RFID data length

XXH

 

 

 

XXH

 

 

XXH

Tag ID + User data

 

:

RFID data

* Data to be read is different depending on the RFID

:

 

read mode setting.

 

XXH

 

 

 

XXH

 

ETX

03H

 

EOT

04H

Indicates the end of the status block.

CR

0DH

 

LF

0AH

 

(4)When an access password is designated using this command, writing data onto a tag cannot be performed if the access password registered in the tag differs from the access password designated. However, reading data can be performed.

(If the tag is the Hibiki tag and read lock is set, reading the tag is also disabled.)

- 117 -