Toshiba B-SX4T-GS20-QM-R manual How to send control code data, 00H 3EH, 40H, 01H 3EH, 41H

Models: B-SX4T-GS20-QM-R

1 374
Download 374 pages 34.06 Kb
Page 340
Image 340

(7)Data Matrix

The code to be used is designated using the format ID.

Format ID

 

 

 

 

Code

 

 

 

 

 

 

Details

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1

 

Numerics

 

 

 

 

 

 

0 to 9

space

 

 

 

 

 

 

 

 

 

2

 

Letters

 

 

 

 

 

 

A to Z

space

 

 

 

 

 

 

 

 

 

3

 

Alphanumerics, symbols

 

 

0 to 9

A to Z

space . , - /

 

 

 

 

4

 

Alphanumerics

 

 

 

 

0 to 9

A to Z

space

 

 

 

 

5

 

ASCII (7-bit)

 

 

 

 

00H to 7FH

 

 

 

 

 

 

 

 

 

6

 

ISO (8-bit)

 

 

 

 

 

 

00H to FFH (Kanji)

 

 

 

[Transfer Code]

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

1

2

 

3

 

4

5

6

 

 

7

8

9

 

A

B

C

D

E

F

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

0

NUL

DLE

SP

 

0

 

@

P

`

 

 

p

 

 

 

 

 

 

 

 

 

 

1

SOH

DC1

!

 

1

 

A

Q

a

 

q

 

 

 

 

 

 

 

 

 

 

2

STX

DC2

 

2

 

B

R

b

 

r

 

 

 

 

 

 

 

 

 

 

3

ETX

DC3

#

 

3

 

C

S

c

 

s

 

 

 

 

 

 

 

 

 

 

4

EOT

DC4

$

 

4

 

D

T

d

 

t

 

 

 

 

 

 

 

 

 

 

5

ENQ

NAK

%

 

5

 

E

U

e

 

u

 

 

 

 

 

 

 

 

 

 

6

ACK

SYN

&

 

6

 

F

V

f

 

v

 

 

 

 

 

 

 

 

 

 

7

BEL

ETB

 

7

 

G

W

g

 

w

 

 

 

 

 

 

 

 

 

 

8

BS

CAN

(

 

8

 

H

X

h

 

x

 

 

 

 

 

 

 

 

 

 

9

HT

 

EM

)

 

9

 

I

Y

i

 

y

 

 

 

 

 

 

 

 

 

 

A

LF

SUB

*

 

:

 

J

Z

j

 

z

 

 

 

 

 

 

 

 

 

 

B

VT

ESC

+

 

;

 

K

[

k

 

{

 

 

 

 

 

 

 

 

 

 

C

FF

 

FS

,

 

<

 

L

\

l

 

 

 

 

 

 

 

 

 

 

 

D

CR

 

GS

 

=

 

M

]

m

 

}

 

 

 

 

 

 

 

 

 

 

E

SO

 

RS

.

 

>

 

N

^

n

 

~

 

 

 

 

 

 

 

 

 

 

F

SI

 

US

/

 

?

 

O

_

o

 

 

 

 

 

 

 

 

 

 

 

 

cHow to send control code data:

NUL

(00H)

>@

(3EH, 40H)

SOH

(01H)

>A

(3EH, 41H)

STX

(02H)

>B

(3EH, 42H)

to

 

 

GS

(1DH)

>]

(3EH, 5DH)

RS

(1EH)

>^

(3EH, 5EH)

US

(1FH)

>_

(3EH, 5FH)

dHow to send a special code:

>

(3EH)

>0 (3EH, 30H)

eHow to send a Kanji code:

Shift JIS

JIS hexadecimal

(For details, refer to the section for the Bar Code Data Command.)

- 360 -

Page 340