gnInit (Printer Host)

z Reset request signal from the host.

z Normally at “High” level. A low on this input causes the printer to be initialized in the same manner as when the power is turned on.

*When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting in the system mode, the printer is not initialized even if it receives a low signal.

zWhen the nInit signal is input during printing, the printer completes printing one tag/label which is being printed, cancels the next processing, then is initialized in the same manner as when the power is turned on.

*When “Reset process when the nInit signal is ON” is set to “OFF” in the parameter setting in the system mode, the next process proceeds without being canceled.

zMinimum pulse width of 0.5 µsec.

hSelect (Printer Host)

z This is an output signal which indicates whether the printer is in Pause state or placed online. The printer can receive data while placed online.

z The signal is at “Low” level while the printer is in a Pause state.

z The signal is kept at “Low” level (in a Pause state) until the current state (one of the following states) is reset.

Pause state caused by the [PAUSE] key

Paper end state

Ribbon end state

Head open state

Printer error state

Initialization in progress upon power on or receipt of the nInit signal

inFault (Printer Host)

z Output signal indicating that the printer is in a Fault state. z At “Low” level while the printer is in a Fault state.

z The signal is kept at “Low” level (in a Fault state) until the current state (one of the following states) is reset.

Pause state caused by the [PAUSE] key

Paper end state

Ribbon end state

Head open state

Printer error state

Initialization in progress upon power on or receipt of the nInit signal

jPError (Printer Host)

z Output signal indicating a label end or ribbon end state.

z At “High” level when the printer is in a label end or ribbon end state. z Turns to “Low” level when the label end or ribbon end state is reset.

k+5 V

z This is not a signal but a +5 V power supply voltage. z The maximum current of 500 mA can be taken out.

nSelectIn (Printer Host) z Not used

11nAutoFd (Printer Host) z Not used

- 17 -

Page 21
Image 21
Toshiba B-SX4T-GS20-QM-R manual