LCD Message of |
|
| Detail Status | |
Upper Line |
| Printer Status | Auto Status | Status |
(English) |
|
| Transmission | Request |
|
|
|
| Command |
|
|
|
| |
EEPROM ERROR | An EEPROM for back up cannot be read/written | – | – | |
| properly. |
|
| |
SYSTEM ERROR | (a) A command has been fetched from an odd | – | – | |
|
| address. |
|
|
| (b) | Word data has been accessed from a place |
|
|
|
| other than the boundary of the word data. |
|
|
| (c) | Long word data has been accessed from a |
|
|
|
| place other than the boundary of the long word |
|
|
|
| data. |
|
|
| (d) | An undefined command in a place other than |
|
|
|
| the delay slot has been decoded. |
|
|
| (e) | An undefined command in the delay slot has |
|
|
|
| been decoded. |
|
|
| (f) | A command which rewrites the data in the |
|
|
|
| delay slot has been decoded. |
|
|
- | A void pattern printing is completed. | 60 | ||
| When data cannot be written onto the RFID tag |
|
| |
| properly, the printer prints the void pattern to |
|
| |
| indicate that this tag is faulty, and then, |
|
| |
| automatically retries according to the setting for the |
|
| |
| maximum number of RFID write retries. When the |
|
| |
| void pattern printing is completed, the printer sends |
|
| |
| this status. |
|
| |
RFID WRITE ERROR | When writing data onto the RFID tag continuously | 61 | 61 | |
| failed for the maximum number of RFID write |
|
| |
| retries, the printer enters an error state and sends |
|
| |
| this status. |
|
| |
RFID ERROR | When the printer cannot communicate with the | 62 | 62 | |
| RFID module, due to a failure of the RFID module |
|
| |
| or some other reasons, this error occurs. |
|
| |
- | Writing data onto an RFID tag succeeded. | |||
| When a data write, performed by an RFID Data |
|
| |
| Write Command (@012), succeeded, this status is |
|
| |
| returned. |
|
| |
- | Writing data onto an RFID tag failed. | |||
| When a data write, performed by an RFID Data |
|
| |
| Write Command (@012), failed, this status is |
|
| |
| returned. |
|
| |
INPUT PASSWORD | The printer is waiting for a password to be entered. | |||
PASSWORD INVALID | Password entered was not correct consecutively for | |||
| three times. |
|
| |
RFID CONFIG ERR | 65 | 65 | ||
| RFID module’s destination code is not specified |
|
|
- 270 -