6.4.2 FINE ADJUSTMENT VALUE SET COMMAND [ESC] Z2; 2

Function

Format

Term

Sets various fine adjustment values on the printer.

[ESC] Z2; 2, abbbcdddeffghhhijjkllmnnoppqqrr [LF] [NUL]

a:Indicates the direction, forward or backward, in which a feed length fine adjustment is to be made.

+: Backward

-: Forward

bbb:Feed length fine adjustment value

000 to 500 (in units of 0.1 mm, in steps of 0.5 mm) (*1)

c:Indicates the direction, forward or backward, in which a cut position (or strip position) fine adjustment is to be made.

+: Backward

-: Forward

ddd: Fine adjustment value for the cut position (or strip position) 000 to 500 (in units of 0.1 mm, in steps of 0.5 mm) (*1)

e:Indicates whether the back feed is to be increased or decreased. +: Increase

-: Decrease

ff:Back feed length fine adjustment value

00 to 95 (in units of 0.1 mm, in steps of 0.5 mm) (*1)

g:Indicates the direction, positive or negative, in which the X-coordinate fine adjustment is to be made.

+: Positive direction

-: Negative direction

hhh: X-coordinate fine adjustment value

000 to 995 (in units of 0.1 mm, in steps of 0.5 mm) (*1)

i:Indicates whether to increase or decrease the density in the thermal transfer print mode.

+: Increase (darker)

-: Decrease (lighter)

jj:Print density fine adjustment value (for the thermal transfer print mode) 00 to 10 (in units of 1 step)

k:Indicates whether to increase or decrease the density in the direct thermal print mode.

+: Increase (darker)

-: Decrease (lighter)

ll:Print density fine adjustment value (for the direct thermal print mode) 00 to 10 (in units of 1 step)

m:Fine adjustment direction for the ribbon rewind motor voltage

-: Fixed as Negative (The voltage is lowered.)

nn:Fine adjustment value for the ribbon rewind motor voltage 00 to 15 (in units of 1 step)

- 243 -

Page 247
Image 247
Toshiba B-SX4T-GS20-QM-R manual Fine Adjustment Value SET Command ESC Z2