Supplemental explanation of parameter “I”

When Gen2 tag is used, options for the parameter “I” are as follows: I1: TID & User area data

I2: EPC data

I3: EPC data + TID & User area data

As the readability of the TID & User area differs depending on the tag manufacturers, refer to the memory map of each tag.

Example)

In the case of OMRON’s Gen2 tag

4-byte TID area is readable, and the user area is read/write protected.

In the case of HITACHI’s Gen2 tag (Hibiki)

8-byte TID area is readable/writable and 30-byte user area is readable/writable.

(4) The format of information to be returned to the host is as follows.

SOH

01H

Start of the status block

STX

02H

 

“F”

46H

 

 

 

30H30H: Reading failed.

 

30H

31H31H: I-Code

 

31H32H: Tag-it

 

 

 

 

31H33H: C220

Tag

 

31H34H: ISO15693

 

31H35H: C210

 

type

 

31H36H: C240

 

 

31H37H: C320

 

30H

32H31H: EPC Class 0

 

 

32H32H: EPC Class 1

 

 

32H33H: ISO18000-6B

 

 

32H34H: EPC Class 1 Generation 2

Data

---

Tag data (0 bytes to 9999 bytes)

ETX

03H

 

EOT

04H

End of the status block

CR

ODH

 

LF

OAH

 

- 252 -