Chapter 39 AAA Server
Bind DN
A bind DN is used to authenticate with an LDAP/AD server. For example a bind DN of cn=zywallAdmin allows the ZyWALL to log into the LDAP/AD server using the user name of zywallAdmin. The bind DN is used in conjunction with a bind password. When a bind DN is not specified, the ZyWALL will try to log in as an anonymous user. If the bind password is incorrect, the login will fail.
39.2.1 Configuring Active Directory or LDAP Default Server SettingsTo configure the Active Directory or LDAP default server settings, click Object > AAA Server > Active Directory (or LDAP) to display the screen as shown.
Figure 464 Object > AAA Server > Active Directory (or LDAP) > Default
The following table describes the labels in this screen.
Table 211 Object > AAA Server > Active Directory (or LDAP) > Default
LABEL | DESCRIPTION |
Host | Enter the IP address (in dotted decimal notation) or the |
| name (up to 63 alphanumerical characters) of an AD or LDAP server. |
|
|
Port | Specify the port number on the AD or LDAP server to which the ZyWALL sends |
| authentication requests. Enter a number between 1 and 65535. The default is 389. |
|
|
Bind DN | Specify the bind DN for logging into the LDAP server. Enter up to 63 |
| alphanumerical characters. |
| For example, cn=zywallAdmin specifies zywallAdmin as the user name. |
Password | If required, enter the password (up to 15 alphanumerical characters) for the |
| ZyWALL to bind (or log in) to the AD or LDAP server. |
|
|
Base DN | Specify the directory (up to 63 alphanumerical characters). For example, |
| o=ZyXEL, c=US. |
CN Identifier | Specify the unique common name that uniquely identifies a record in the AD or |
| LDAP directory. Enter up to 63 alphanumerical characters. |
|
|
Search time limit | Specify the timeout period (between 1 and 300 seconds) before the ZyWALL |
| disconnects from the AD or LDAP server. In this case, user authentication fails. |
| The search timeout occurs when either the user information is not in the LDAP |
| server or the server is down. |
|
|
628 |
| |
ZyWALL USG 100/200 Series User’s Guide |
| |
|
|
|