Appendix A Log Descriptions

 

Table 287 IDP Logs (continued)

 

LOG MESSAGE

DESCRIPTION

 

IDP system-protect

An update of the IDP system-protect signatures succeeded. The

 

signature update from

previous and updated signature versions are listed.

 

version <version> to

 

 

version <version> has

 

 

succeeded.

 

 

System-protect error.

The IDP system-protect function had an error. Creation of the IDP

 

Create IDP debug

debug directory failed.

 

directory failed

 

 

System internal error.

There was an internal system error. Creation of an IDP statistics

 

Create IDP statistics

entry failed.

 

entry failed.

 

 

System-protect error.

The IDP system-protect function had an error. The device did not

 

Out of memory. IDP

have enough available memory. The setting for IDP activation has

 

activation unchanged.

not changed.

 

System-protect error.

Activation of the IDP system-protect function failed due to an internal

 

Create IDP proc failed.

system error.

 

IDP activation failed.

 

 

from <zone> to <zone>

The ZyWALL detected an intrusion in traffic traveling between the

 

[type=<type>] <message>

specified zones.

 

, Action: <action>,

The <type> = {scan-detection(<attack>) flood-detection(<attack>)

 

Severity: <severity>

http-inspection(<attack>) tcp-decoder(<attack>)}.

 

 

The <message> gives details about the attack, although the

 

 

message is dropped if the log is more than 128 characters.

 

 

The <action is what the ZyWALL did with the packets.

 

 

The <severity> is the threat level (very low, low, medium, high, or

 

 

severe).

 

 

 

 

Program DFA failed.

There was an internal system error. The IDP search engine failed.

 

IDP signature update

An attempt to update the IDP signatures failed because the device

 

failed. Fail to extract

could not extract the signature package’s temporary file.

 

temporary file.

 

 

IDP signature update

An attempt to update the IDP signatures failed due to an internal

 

failed.

system error.

 

IDP signature update

An attempt to update the IDP signatures failed due to an internal

 

failed. Invalid

system error.

 

signature content.

 

 

System internal error.

There was an internal system error.

 

Create IDP traffic

 

 

anomaly entry failed.

 

 

Query signature version

The device could not get the signature version from the new

 

failed.

signature package it downloaded from the update server.

 

Can not get signature

The device could not get the signature version from the new

 

version.

signature package it downloaded from the update server.

 

IDP system-protect

An IDP system-protect signature update failed.

 

signature update

 

 

failed. Invalid IDP

 

 

config file.

 

 