46 Chapter 2
One-Button Measurement Functions
Mode Setup (Spectrum Analysis Mode)
One-Button Measurement Functions
2.1.2 Radio Std Setup
Accesses the key menu for selecting the device, packet type, or signal bandwidth to be
measured.
Key Path: Mode Setup
History: Modified with PSA firmware revision A.04.00
Added with PSA firmware revision A.02.00
Modified with ESA firmware revision A.08.00
Added with ESA firmware revision A.07.00
Remote Command:
There is no equivalent remote command.
2.1.2.1 Signal BW
Allows you to set the measurement bandwidth when Radio Std (None) is selected. This
function is available only when you select None as the standard.
Key Path: Mode Setup, Std Setup
Factory Preset: 3.0 MHz
Default Terminator: Hz
Range: The non-zero span range of the analyzer
History: Modified with PSA firmware revision A.04.00
Added with PSA firmware revision A.02.00
Modified with ESA firmware revision A.08.00
Added with ESA firmware revision A.07.00
Remote Command:
[:SENSe]:RADio:STANdard:SBWidth <freq>
[:SENSe]:RADio:STANdard:SBWidth?
Example: RAD:STAN:SBW 2MHZ