Chapter 2 65
One-Button Measurement Functions
MEASURE (Spectrum Analysis Mode)
One-Button Measurement Functions
Radio Std None
or
Radio Std = None and
more than one offset is
on
Meas Type = Total Pwr
Ref
Returns 28 values that correspond in the
following order:
1. Main Channel- relative power spectral
density (dB)
2. Main Channel- power spectral density
(dBm/Hz)
3. Main Channel- relative power spectral
density (dB)
4. Main Channel- power spectral density
(dBm/Hz)
5. Negative Offset Frequency (1) -
relative power spectral density (dB)
6. Negative Offset Frequency (1) -
power spectral density (dBm/Hz)
7. Positive Offset Frequency (1) -
relative power spectral density (dB)
8. Positive Offset Frequency (1) -
power spectral density (dBm/Hz)
...
1. Negative Offset Frequency (6)
- relative power (dB)
2. Negative Offset Frequency (6)
- absolute power (dBm)
3. Positive Offset Frequency (6)
- relative power (dB)
4. Positive Offset Frequency (6)
- absolute power (dBm)
Main channel relative power is relative to
the main channel power spectral density,
and therefore is always equal to 0.00 dB.
If Method = Fast Returns 5 comma-separated results, in the
following order:
Main Carrier - absolute power (dBm)
Negative offset frequency (1)
- absolute power (dBm)
Positive offset frequency (1)
- absolute power (dBm)
Negative offset frequency (2)
- absolute power (dBm)
Positive offset frequency (2)
- absolute power (dBm)
Measurement Results Available (Continued)
Condition Command Results Returned