Chapter 2 85
One-Button Measurement Functions
MEASURE (Spectrum Analysis Mode)
One-Button Measurement Functions
Using Total Power
Reference n=6 Total Power Reference
Returns 12 comma-separated scalar values (in dBc) of the power
relative to the carrier at the segment frequencies (14 when offset F
is active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
…
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
Using Power
Spectral Density
Reference
n=6 Power Spectral Density Reference
Returns 12 comma-separated scalar values (in dBc/Hz) of the
power relative to the carrier at the segment frequencies (14 when
offset F is active). Returns –999.0 for the offsets in WLAN
standard:
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
…
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
n=7 Returns 12 comma-separated pass/fail test results (0 =passed, or
1 =failed) determ ined by testing the absolute power in each offset
against the specified offset’s absolute power limits (14 when offset
F is active):
1. Reserved for the future use, returns –999.0
2. Reserved for the future use, returns –999.0
3. Negative offset frequency (A)
4. Positive offset frequency (A)
…
11.Negative offset frequency (E)
12.Positive offset frequency (E)
If offset F is active:
13.Negative offset frequency (F)
14.Positive offset frequency (F)
Measurement Results Available (Continued)
Command /
Condition n Results Returned